Laserfiche WebLink
REVISIONS <br /> FINISH SCHEDULE DOOR SCHEDULE <br /> DOOR FRAME <br /> ROOM FLOOR BASE WALLS _ CEILING REMARKS R SIZE FRAME FRAME DETAIL FIRE RBATING EL HADOOR RDWARE NOTES DOOR # <br /> S _ , DOOR # LOCATION TYRE W H MATERIAL FINISH MATERIAL FINISH HEAD JAMB THRESHOLD <br /> w O ❑ G] Z 1 HALL TO RESTROOM 1 A 3'-0" 8'0" WOOD PL METAL F 12/AD2 12/AD2 <br /> Lu <br /> Q m m co 00 d 2 HALL TO RESTROOM 2 A 38'-0" WOOD 8'-0WOOD PL METAL F 12/AD2 12/AD2 - - 1 - 2 I <br /> w 0 A ?� r Lu Ow 3 DRY STORAGE TO EQUIPMENT B 3'-0" 8'-0" WOOD PL METAL F 121AD2 12/AD2 = 2 _ 3 <br /> U J z C7 U O ¢ z E FRONT ENTRY AND REAR - 3'-fl" - - - - - 3 E j <br /> O "'"' a r � <br /> r > - <br /> U m m w Z In caz ZEDO <br /> Zw w w m En t r Ln v u� ti N 04 <br /> 0 Z <br /> � w O w a Q C3 i i G] o Ll Ch "u l p Ch Q <br /> � N J U O or m w w cK m J w � m a = rr m � = m � LL THIS DOCUMENT,AND THE IDEAS AND DESIGNS <br /> r Q O uj Q_ r- J IY J J C 0- J r O <br /> Lu <br /> uj INCORPORATED HEREIN,AS AN INSTRUMENT OF <br /> PROFESSIONAL SERVICE,IS THE PROPERTY OF <br /> o r J > J J T = O a i AND IS NOT TO BE USED, IN WHOLE OR IN <br /> a w ' ' O f' U � C9 U w ~ <br /> ul O U Z '� O ao Z O LU rz O Z O Z ar `'� d <br /> O ' « � m l L L0 1-.- .4 ul i- U_ �_- ' his O PART, FOR ANY OTHER PROJECT WITHOUT <br /> z - _ LL _ _�__ - -.- .-.-.- ._..._ _ _ _ -___ --_ _ NOTES: FINISH LEGEND WRITTEN AUTHORIZATION. <br /> D <br /> CA <br /> 101 FE SEE FINISH NOTE 19� �- SF = STOREFRONT DOOR F = FACTORY FINISH <br /> 5C = SELF CLOSER S = FIELD STAIN <br /> 102 SERVICE -._ ® � � � ® _ PLANNING ■ ■ ■ <br /> 103 DRIVE-THRU SERVICE ® ® • ® - - PB = PANIC BAR FP = FACTORY PRIME&FIELD FINISH ARCHITECTURE <br /> --�- 20 MIN. = 20 MIN.EIRE RATED PL =PLASTIC LAMINATE FINISH <br /> 104 PREP <br /> 105 DRY STORAGE ® ® DOOR ASSEMBLY <br /> ® = <br /> 45 MIN = 45 MIN.FIRE RATED FFP FIELD PRIME&PAINT <br /> 106 EQUIPMENT • i DOOR ASSEMBLY <br /> 107 HALL ® ® 60 MIN = 60 MIN.FIRE RATED <br /> 108 DOOR ASSEMBLY <br /> RESTROOM I ® ! • ON 2 WALLS-SEE INT.ELEVS. <br /> 109 i ® ® ® ON 2 WALLS-SEE INT.ELEVS. 90 MIN = 90 MIN.FIRE RATED <br /> MIN.+4-9'HIGH TILL WAINSCOT DOOR ASSEMBLY <br /> RESTROOM 2 <br /> 3 HR - RATED3 HOUR FIRE <br /> DOOR ASSEMBLY <br /> -- KP=KICK PLATE AT PUSH SIDE. ARCHITECTURE PLUS INC. <br /> 4335-B NORTH STAR WAY <br /> DOOR TYPES SCALE: 1/4"=1'-0" ph. 209.577.4661 <br /> fx. 209.577.0213 <br /> ACCESSIBLE www.apiarc.com <br /> RESTROOM <br /> SIGNAGE-MOUNT <br /> IGNAGE-MOUNT <br /> Y-U'AFF TO nn <br /> CENTERLINE E \ <br /> HARDWARE HARDWARE <br /> FRANK C.BOOTS <br /> JOSEPH L.SMITH <br /> FINISH NOTES <br /> RODNEY C.ALonlzo <br /> ARCHITECTS <br /> FLUSH PANEL DOOR FLUSH PANEL DOOR '� <br /> Q <br /> 1. USE SCHLUTER TRANSITION STRIPS AT CHANGE OF FLOORING MATERIAL. u <br /> 2. DOORS TO BE FLUSH DESIGN WITH PLASTIC LAMINATE FINISH.SEE DOOR NOTES ON THIS SHEET <br /> 3. PLASTIC LAMINATE CA31NFTS TO HAVE WHITE MELAMINE INTERIORS_ A B uj <br /> II. <br /> 4. PAINT FINISH TO BE SEMI GLOSS ENAMEL. <br /> 5. GYPSUM BOARD WALL TEXTURE TO BE VERY LIGHT STIPPLE FINISH. <br /> 6. PAINT ALL RECESSED CAN TRIMS,VENTS AND REGISTERS IN SOFFITS/CEILINGS TO MATCH SOFFIT/CEILING COLOR. O <br /> 7. ACCESSIBLE SIGNAGE FOR RESTROOM TO BE BLACK WITH WHITE LETTERING(BLUE NOT ACCEPTABLE). DOOR HARDWARE DOOR NOTES Lu ce <br /> 8. SEE PLUMBING DRAWINGS FOR ALL PLUMBING SELECTIONS. uj Lu__ <br /> 9. ELECTRICAL PLATES AND RECEPTACLES TO BE WHrrE.SWITCHES TO BE DECORA STYLE,COLOR TO BE WHITE.SEE ELECTRICAL DRAWINGS FOR ADDITIONAL SPECIFICATIONS. U. = <br /> 10. FLOOR,WALL AND CEILING MATERIAL SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS PER C.B.C.TABLE 803.9. 0 <br /> HARDWARE GROUPS: BUILDING DEPARTMENT NOTES: U. " <br /> E 1. LEVER LOCK SET(ANSI F76 PRIVACY FUNCTION), 1.5 PR HINGES,CLOSER,WALL STOP,INTERIOR DOOR SWEEP(FOR 1_ ALL EXITS ARE TO 8E OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. H <br /> ii. CONTRACTOR TO REPAIR ALL EXISTING FINISHES AS REQUIRED TO MATCH ADJACENT EXISTING FINISHES. f. i ACOUSTICS),ACCESSIBLE SIGNAGE,SILENCERS (STRIKE SIDE) u <br /> 2. ALL HAND-ACTIVATED DOOR HARDWARE TO BE CENTERED BETWEEN 34"AND 44"A.F.F.AND BE LEVER, <br /> LLJ <br /> 12. GYPSUM BOARD TO BE 5/8"THICK.USE MOISTURE RESISTANT GYPSUM BOARD IN WET AREAS, 2. LOCKSET(ANSI F86 STOREROOM FUNCTION), 1.5 PR HINGES,STOP,SILENCERS (STRIKE SIDE} PANIC-BAR OR PUSH/PULL PER CSC 1111404.2.7 AND 11B-309.4. <br /> A. 5/8"GYPSUM BOARD-TAPE,TEXTURE,PRIME,PAINT.PROVIDE LIGHT ORANGE PEEL FINISH-SUBMIT FULL SIZE SAMPLE I MOCK-UP FOR TENANT APPROVAL-TYPICAL <br /> 3. ALL HARDWARE IS EXISTING AND ACCESSIBLE:ENTRY DOORS HAVE PUSH/PULL AND REAR DOOR HAS RIM EXIT DEVICE 3. THE LOWER 10"OF ALL DOORS SHALL COMPLY WITH CBC 118404.2.10. .. N <br /> B. "USG,MOLD TOUGH"OR APPROVED EQUAL-5/8"MOISTURE RESISTANT GYPSUM BOARD-TAPE,TEXTURE,PAINT-PROVIDE LIGHT ORANGE PEEL FINISH- z CV <br /> SUBMIT FULL SIZE SAMPLE/MOCKUP FOR TENANT APPROVAL-TYPICAL 4. ALL DOORS TO HAVE MINIMUM 18"STRIKE SIDE CLEARANCE AT INTERIOR AND 24"AT EXTERIOR. N <br /> 5. MAXIMUM EFFORT TO OPERATE DOORS SHALL BE NOT GREATER THAN: <br /> C. "USG,DUROCK"OR APPROVED EQUAL-5/8"CEMENT BACKER BOARD AT TILE FINISH NOTE: <br /> I+ � HARDWARE FINISH: 5LB AT EXTERIOR DOORS,5LB AT INTERIOR DOORS AND 15LB AT FIRE DOORS PER CBC 118404.2.9. <br /> 14. RESTROOM ACCESSORIES SHALL BE FURNISHED AND INSTALLED ICY THE GENERAL CONTRACTOR. OIL RUBBED BRONZE-VERIFY WITH TENANT I 6, PROVIDE SIGN AT ENTRY DOORS STATING"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" Z <br /> 15. SUSPENDED GRID CEILING SHALL BE 15116"GRID WITH 24!'x 48""VINYLROCK"OR OTHER APPROVED WASHABLE CEILING PANELS. 7, DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES,THE TIME IL <br /> REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. <br /> 16. INTERIOR FINISHES OF ALL AREAS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 200 AND SMOKE DEVELOPMENT RATINGOF 450(CLASS C) <br /> 8. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES,THE DOOR OR <br /> 17. DECORATIVE MATERIALS,INCLUDING DRAPES AND HANGINGS,MUST BE NONCOMBUSTIBLE,FLAME RESISTANT OR TREATED WITH A FLAME RETARDANT PER CFC 2404.2 AND TITLE 19 SEC.3.06 GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM. <br /> 18. WALL BASE: 1 X 6 STAIN GRADE,CHAMFER TOP (VERIFY SPECIES AND STAIN WITH TENANT) 9. THE INTERIOR DOORS TO ALL UNCONDITIONED ROOMS SHALL HAVE FULL WEATHER SEALS AT THE DOOR ASSEMBLIES <br /> 19_ AT AREAS OF OPEN CEILING,ALL EXPOSED ROOF FRAMING, ELECTRICAL CONDUIT, DUCTS,INSULATION,SOFFIT FRAMING,ETC.SHALL BE PAINTED. 10. THE LEVER OF LEVER ACUTUATED LATCHES OR LOCKS SHALL BE CURVED WITH A RETURN TO WITHIN 1/2 INCH OF THE DOOR <br /> TO PREVENT CATCHING ON THE CLOTHING OF PERSONS DURING EGRESS CBC 1010.1.9.1. <br /> 20. COVE BASE AT RFSTROOM WALL TTLETO BE SCHLUTER DILFX-AHKA. <br /> 21. ALL COVE BASE MATERIAL TO HAVE MINIMUM 3/8"RADIUS. <br /> DOOR NOTES / SPECIFICATIONS: w <br /> 22. SANITARY COVE BASE AT SERVICE AND DRIVE THRU SHALL BE APPROPRIATE FOR USE WITH CONCRETE FLOOR, WITH TAPERED BASE EDGE TO FLOOR.MATCH COLOR AND DIMENSIONS OF TILE BASE AT PREP AND DRY STORAGE AREA J <br /> 1. INTERIOR SOLID CORE WOOD DOORS:'T.M.COBB"OR APPROVED EQUAL 13/4"THICK WITH PLASTIC LAMINATE:WILSONART, 0 <br /> 23. WALL AND CEILING PAINT IN FOOD SERVICE, PREP,SCULLERY,STORAGE,JANITOR,AND RESTROOMS SHALL BE SEMI-GLOSS. CAFELLE;7933. w <br /> z <br /> 2. INTERIOR METAL DOOR FRAMES:"WESTERN INTEGRATED"SERIES 300 OR 400 AS APPROPRIATE OR APPROVED EQUAL-FINISH TO BE vVi <br /> FACTORY BRONZE ANODIZED. _ <br /> sa <br /> 3. VERIFY ALL HARDWARE FINISHES WITH TENANT. p <br /> Z <br /> 4. VERIFY ALL DOOR STYLES AND MATERIALS WITH TENANT. Q <br /> CASEWORK 0 <br /> 1 -ALL CABINET WORK SHALL BE CONSTRUCTED TO W.I.C.CUSTOM GRADE 5. SEE DOOR SCHEDULE FOR RATINGS. O <br /> 2_CABINETS SHALL BE FLUSH OVERLAY CONSTRUCTION <br /> 3-ALL INTERIOR SURFACES OF CABINET SHALL BE MELAMINE SURFACED <br /> I <br /> 4-ALL CABINET DOORS AND DRAWERS SHALL BE EDGE-BANDED I <br /> 5-PULLS SHALL BE OIL RUBBED BRONZE FINISH,4-WIRE PULL` <br /> I <br /> 6-HINGES SHALL BE ADJUSTABLE INTERIOR TYPE,NON-VISIBLE WHEN DOORS ARE CLOSED II j <br /> 7-ADJUSTABLE SHELVING SHALL BE FINISHED WOOD WITH ADJUSTABLE HARDWARE CONSISTING OF RABBETED STANDARDS AND STEEL SHELF CLIPS-VERIFY FINISH AND 1 <br /> REQUIREMENTS WITH TENANT ! CID <br /> p <br /> 0 <br /> U <br /> 8-SUBMIT COLORS TO TENANT FOR APPROVAL <br /> 0 <br /> PAINT <br /> 1 -PREMIUM 3 COAT PAINT SYSTEM <br /> C& <br /> (1) COAT PRIMER(SEALER <br /> d <br /> (2) COATS SEMI-GLOSS <br /> DATE: SEPTEMBER 2018 <br /> NOTE: <br /> 1. PAINT COLORS TO BE APPLIED ON SAMPLE TEST AREA-OBTAIN APPROVAL FROM TENANT PRIOR TO COMMENCING WORK. <br /> )013 NO. : 1 B-091 <br /> 2, COLORS FOR FOOD PREP AND STORAGE AREAS,BAR,RESTROOMS,AND EMPLOYEE LOCKER AREA SHALL BE APPROVED BY ENVIRONMENTAL HEALTH. <br /> 0 <br /> i Q <br /> DRAWN : B. ROSENBERGER <br /> I <br /> j� CHECKED: J. SMITH <br /> 1 <br /> SHEET: E <br /> U <br /> O <br /> O <br /> t <br /> U <br /> C <br /> O <br /> U <br /> A5 * 0a <br /> i <br /> a <br /> i <br /> ,nn ap[COPYR[GHT 2017 ��+ � <br />