4 i <br /> i <br /> 20 March 1996 <br /> i AGE-NC Project No 95-0139 <br /> Page 6 of 6 <br /> ibelow the water table at the northwestern portion of the site pointed to low concentrations of <br /> hydrocarbons in the saturated zone Slight concentrations of residual diesel hydrocarbons were also <br /> i encountered below the water table in the vicinity of boring B7 The detection' of petroleum <br /> hydrocarbons below the water table is a common occurrence, despite the greater density of water, <br /> and is generally attributed to seasonal fluctuation of the water table Remediation for this situation <br /> iis typically included in that for the ground water <br /> We recommend performance of soil and ground water remediation feasibility testing at the site Upon <br /> i completion of feasibility testing, a Corrective Action Plan for soil and ground water remediation can <br /> be prepared <br /> i6.0. LIMITATIONS <br /> iOur professional services were performed using that degree of care and skill ordinarily exercised by <br /> environmental consultants practicing in this or similar localities The findings were based upon <br /> analytical results provided by an independent laboratory Evaluations of the geologic/hydrogeologic <br /> conditions at the site for the purpose of this investigation are made from a limited number of available <br /> data points(i a monitoring wells, soil samples) and subsurface conditions may vary away from these <br /> data points No other warranty, expressed or implied, is made as to the professional <br /> irecommendations contained in this report <br /> i - <br /> i r _ <br /> i <br /> i R <br /> i <br /> i r �� <br />