Laserfiche WebLink
OWNER: Greg Goodman <br /> ADDRESS: 3326 E. Acampo Rd <br /> LOCATION: 250 yds southeast. <br /> AGE OF HOUSE: 15 years <br /> SEPTIC SYSTEM: Yes, consist of a septic tank and leach lines,no problems with system during life of it_ <br /> OWNER John Gwinn <br /> ADDRESS: 3252 E. Acampo Rd <br /> LOCATION: 150 yds south. <br /> AGE OF HOUSE: 54 years <br /> SEPTIC SYSTEM: Yes, originally a cesspool,but years ago switched to a septic tank, leach lines, and dry <br /> a well. No problems with current system. <br /> OWNER: L. Michels <br /> ADDRESS: 3348 E. Acampo Rd <br /> LOCATION: 200 yds southeast. <br /> AGE OF HOUSE: 43 years <br /> SEPTIC SYSTEM: Yes,replaced original system (possibly a cesspool)30 ago years with a septic tank and <br /> leach lines. No problems with system, however added an additional leach line 4 years <br /> ago. <br /> OWNER: Simfenderfer f <br /> ADDRESS: 3376 E. Acampo Rd <br /> LOCATION: 350 yds southeast. <br /> AGE OF HOUSE: 30+ years <br /> SEPTIC SYSTEM: Yes,replaced original system(cesspool)30 years ago with a septic tank and leach lines. <br /> No problems with system. <br /> V. GROUND WATER DEPTH AND TESTING <br /> i� There is an operating well at the north end of the parcel. Depth to ground water was measured on June <br /> 3, 1991 at 62 feet. According to the map of "Lines of Equal Depth to Water in Wells" published spring 1990 <br /> by the San Joaquin County Flood Control and Water Conservation District, the depth to groundwater at this <br /> location is between 50 and 60 feet. <br /> A water sample was obtained from the well at 12:45 am on May 13, 1990. The sample was submitted <br /> to the laboratory and tested for the presence of EDB (ethelylene dibromide) and DBCP (dibromo <br /> chloropropane).which are soil fumigants used in vineyards. A copy of the test results is contained in the <br /> Appendix. The results indicate that both substances tested for were not detected or below the MCL (maximum <br /> concentration limit) allowed by law. <br /> V1. SOIL PROFILE AND PERCOLATION TESTS <br /> A test pit was excavated to a depth of 10 feet at the approximate site of the proposed septic system in <br /> order to determine the soil profile. The test pit was excavated with a Cat 416 backhoe equipped with a 24 inch <br /> bucket. Visual classification of each soil stratum encountered was made in the field by a civil engineer at the <br /> time the test pit was excavated. A description of each soil encountered is contained in the Appendix as Log of <br /> Test Pit. <br /> pERS0 <br /> 2 lip <br /> z w <br /> Q � <br /> P <br /> 4$Soc <br /> f <br />