Laserfiche WebLink
f <br /> i <br /> S Sufficient <br /> 1 7 Insuftcient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTIOIAj �a„^ u,4 1/j <br /> • ] ❑ 6.1 Site Tap showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. v <br /> ❑ 6.2 The mirk um m umber of shallow and deep percolation tests was performed for each parcel. <br /> ,-2- <br /> ❑El <br /> 6.3 Description of the date,time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> Li ❑ 6.4 Description of the date,time and condition of the test hole after the 24-hour soak period(hole still intact, hole dry, <br /> depth to water remaining in hole,etc.) <br /> �1 <br /> El 6.5 The test conl-ormed to SJC Policy EHD 02-02(correct depth,diameter, 2"gravel,6"water refill,correct readings <br /> recorded). . 2 <br /> Or ❑ 6.6 Complete Percolation Test Form (including readings)was provided with REHS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> ❑ 6.7 Discussionofay potential problems predicted and/or the need for an engineered or alternative septic system. <br /> ❑ 6.8 Discussion of percol n rates in relation to the type, size and location of future leach fields needed at the site. <br /> � 3 <br /> 7.0 CONCLUSION SECTION <br /> ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: rac Reviewed Date:-3� <br /> i I <br /> � II <br /> EHD 26-02-003 Page 2 of 3 Soil Suitability Checklist <br />