Laserfiche WebLink
Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> P1 <br /> 5-15-18 3.25 25 4 hr. Satisfactory <br /> Shallow Test perc. rate <br /> P2 <br /> 5-10-18 3.05 16.7 4 hr. Satisfactory <br /> Shallow Test perc. rate <br /> P3 <br /> 5-10-18 3.00 16.7 4 hr. Satisfactory <br /> Shallow Test perc. rate <br /> Note: A satisfactory percolation rate for a "shallow'test is less than or equal to 60 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the percolation test areas have demonstrated satisfactory percolation <br /> • rates for the use of standard septic systems utilizing leach lines and seepage pits in <br /> accordance with the requirements of the San Joaquin County Environmental Health <br /> Department. <br /> Discussion of Septic System Sizing <br /> Future septic system construction should follow the San Joaquin County On-Site <br /> Wastewater Treatment Systems Standards (2017) where applicable. No new <br /> construction is anticipated. <br /> • <br /> LOGE 1826 Page 8 <br />