• CONCLUSIONS AND RECOMMENDATIONS <br /> In summary, the soil conditions in the percolation test locations appear to be suitable for <br /> use with on-site septic systems. Satisfactory soil percolation rates of 16.7, 16.7, and 25 <br /> min/in were observed in the test locations. <br /> The depth of ground water based on recent aquifer levels is estimated to range between <br /> 112 to 142 feet below ground surface. The ground-water flow is to the west or <br /> northwest at a rate of approximately eight to 10 feet per mile. <br /> A water sample was collected from the domestic water well in August 2017. A second <br /> water sample was collected from the same well in May 2018. Nitrate was detected in <br /> the first sample at a concentration of 12.0 mg/L-N, slightly above the MCL of 10 mg/L-N. <br /> DBCP was not detected in the sample. Nitrate was detected in the second sample at a <br /> concentration of 6.8 mg/L-N, well below the MCL. <br /> We believe the Site suitable for the use of standard septic systems utilizing leach lines <br /> and seepage pits. No new construction is anticipated. <br /> • <br /> • <br /> LOGE 1826 Page 9 <br />