Geological Technics Inc. Page 5 <br /> M C&B Equipment <br /> Monitoring Well Installation Report <br /> Project No.336.2 <br /> November 13,1995 <br /> is entering the well. These water quality parameters were measured at intervals of <br /> each well volume purged (Appendix D-Field Logs). -7 <br /> /2 <br /> A pre-cleaned stainless steel bailer was used to collect each sample. Care wf-be- <br /> taken to minimize sample agitation from the initial filling of the bailer to the transfer <br /> of the sample to the VOA vial and glass amber liter bottles. Once the sample <br /> container was filled and capped, the bottle was inverted, tapped, and checked for <br /> head space bubbles. The sample container was identified and labeled with a unique <br /> designation, inserted into foam holders and placed in an ice chest cooled to 4°C for <br /> transport to the laboratory. <br /> All non disposable sampling equipment is decontaminated using Alconox detergent <br /> and a steam cleaner before and between uses. The effectiveness of the <br /> decontamination procedure is ensured by using the following quality control <br /> measures: <br /> • Nitrile disposable gloves were used by the technician to collect all samples and <br /> were changed with each sampling event. <br /> • A bailer blank for each well was collected prior to sampling by filling the pre- <br /> '' f'-"''I' cleaned stainless steel bailer with water (provided by the laboratory) and then <br /> filling a VOA vial (provided by the laboratory) using the same procedures for <br /> actual sample collection. <br /> Bailer blanks for each sample, along with a trip blank (prepared from water <br /> provided by the laboratory poured into a VOA vial on site), accompanied the <br /> samples to the laboratory and served as checks against cross contamination. A chain <br /> of custody document, listing all samples collected, accompanied the samples from <br /> >? field to laboratory, thereby providing a means to track their movement and insure <br /> their integrity. <br /> : 1 All water purged from each monitoring well and not used as a sample, was placed <br /> in a 55 gallon DOT approved container, properly labeled and stored on site. <br /> l <br /> i <br /> ' I <br />