My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012165
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BRANDT
>
12505
>
2600 - Land Use Program
>
PA-1800204
>
SU0012165
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:39 AM
Creation date
9/4/2019 10:35:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012165
PE
2631
FACILITY_NAME
PA-1800204
STREET_NUMBER
12505
Direction
E
STREET_NAME
BRANDT
STREET_TYPE
RD
City
LOCKEFORD
Zip
95237-
APN
05132010
ENTERED_DATE
1/29/2019 12:00:00 AM
SITE_LOCATION
12505 E BRANDT RD
RECEIVED_DATE
2/1/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\B\BRANDT\12505\PA-1800204\SU0012165\APPL.PDF \MIGRATIONS\B\BRANDT\12505\PA-1800204\SU0012165\CDD OK.PDF \MIGRATIONS\B\BRANDT\12505\PA-1800204\SU0012165\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1) Access driveways shall have a width of no less than twenty-five (25) feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty(20)feet wide. (Development Title Section 9-1015.5[h][1]) <br /> F. LIGHTING: Lighting shall be provided and comply with the following: <br /> 1) If the parking area is to be used at night, parking lot lighting shall be installed. (Development <br /> Title Section 9-1015.5[g]) <br /> 2) Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that <br /> such light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> G. LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> 1) This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> Requirement per California Code of Regulations,Title 23, Division 2, Chapter 2.7. <br /> 2) A minimum ten (10) foot wide landscaped strip shall be installed across the frontage of Brandt <br /> Road, along the project site. (Development Title Section 9-1020.5[c]) <br /> 3) Areas of the property which are not part of the project shall be barricaded from traffic and kept <br /> mowed and dust free. <br /> H. SCREENING: Screening shall be provided and comply with the following: <br /> 1) All storage materials and related activities, including storage areas for trash, shall be enclosed <br /> by a screen six (6) to eight (8) feet in height. Items stored within one hundred (100) feet of a <br /> dedicated street or residential zone shall not be stacked higher than two (2) feet above the <br /> adjacent screen. (Development Title Section 9-1022.4[e][2][A]) <br /> I. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be included <br /> on the Site Plan. All portions of any sign shall be set back a minimum of five (5)feet from any future <br /> right-of-way line, including any corner cut-off(snipe). (Development Title Section 9-1710.2[g]) <br /> J. BUILDING CODE REQUIREMENTS: This project is subject to the California building code (CBC) <br /> and San Joaquin County Ordinance requirements. The following conditions shall be addressed <br /> prior to submittal of a building permit application to the Building Inspection Division: <br /> 1) A building permit and approved plans for the proposed structure is required. Submit plans, <br /> specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for the proposed building, showing compliance with the 2016 California <br /> Building, Mechanical, Plumbing, Electrical, Energy, Green Building Standards Code and Fire <br /> Codes as may be applicable. The required plans must be complete at the time of submittal. <br /> 2) The plans shall also include the following project information on the cover sheet: <br /> a) Description of proposed use <br /> b) Risk Category of Building <br /> c) Proposed occupancy Group <br /> d) Type of construction <br /> e) Sprinklers (Yes or No <br /> f) Number of stories <br /> g) Building height <br /> h) Allowable floor area <br /> PA-1800204 Conditions of Approval 2 <br />