My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0002522 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CARPENTER
>
3540
>
2600 - Land Use Program
>
SA-01-12
>
SU0002522 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:29:16 AM
Creation date
9/4/2019 10:55:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0002522
PE
2633
FACILITY_NAME
SA-01-12
STREET_NUMBER
3540
Direction
E
STREET_NAME
CARPENTER
STREET_TYPE
RD
City
STOCKTON
APN
17916047
ENTERED_DATE
10/29/2001 12:00:00 AM
SITE_LOCATION
3540 E CARPENTER RD
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CARPENTER\3540\SA-01-12\SU0002522\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> k'q KLEINEELDER <br /> y <br /> ' Control and Water Conservation District show groundwater levels in the project area ranging <br /> from about 50 to 100 feet below ground surface from Spring 1981 to Spring 1999. <br /> FIELD EXPLORATIONS AND TESTING <br /> The subsurface conditions at the site were explored on June 10, 2002, by drilling one soil <br /> classification boring to a depth of approximately 20 feet below existing grade. The boring was <br /> ' drilled using a Simco 2400 truck-mounted drill rig equipped with 6-inch O.D. solid-stem auger. <br /> During the same time period, percolation borings were drilled near the soil classification boring <br /> to depths of about 3.5 feet below site grade at two locations on the property. Additional deeper <br /> percolation test holes were also drilled at the same locations in case the shallow borings did not <br /> percolate. The locations of the percolation tests are approximately 200 feet south and 20 feet <br /> east of the northwest property corner and approximately 220 feet north and 40 feet west of the <br /> Y 'southwest'property comer.—The approximate percolation test-locations are presented as P-1 and - <br /> P-3 on the attached plate. <br /> Based on our findings, the subsurface soils encountered consisted of dark gray/brown to light <br /> brown sandy silt to sandy clays to a depth of about 4.5 feet below existing site grade, underlain <br /> C by light brown clayey sand to a depth of about 12.5 feet. These soils were underlain by light <br /> brown sandy clay to the depth explored. <br /> The percolation tests were performed on June 11, 2002, in accordance with accepted guidelines <br /> using clear potable water. The procedure calls for first placing about 2 inches of fine gravel at <br /> the bottom of the borehole. The hole is then pre-soaked with water at least 24 hours prior to <br /> performing the test. From a fixed reference point, the drop in water level is measured in <br /> approximate 30-minute intervals for four hours, refilling as necessary to maintain the prescribed <br /> amount of water over the gravel. Under the observation of a sanitarian from the San Joaquin <br /> County Public Health Services, Environmental Health Division (SJCPHS/EHD), the last 30- <br /> minute reading of the four hour period is recorded and used to calculate the percolation rate in <br /> minutes per inch. The estimated percolation rates are summarized below. A copy of our field <br /> percolation test results signed by a representative from SJCPHS/EHD is attached. <br /> Test.Number De th,` Peireolati`on,Rate;min:liia b <br /> P-1 3.5 36 <br /> P-3 3.5 31 <br /> Following our percolation testing, a representative with our firm obtained a sample of <br /> groundwater using clean procedures from a spigot located adjacent to a well estimated to be 150 <br /> feet south and 100 feet east of the property's northeast corner. The same day, the water sample <br /> was submitted to Sequoia Analytical using chain-of-custody procedures for DBCP and nitrate <br /> testing. The results of our tests and a copy of the chain-of-custody are attached. <br /> M <br /> 17284.GO1/ST02R203 July 10,2002 <br /> ©2002 Kleinfelder,Inc. Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.