Laserfiche WebLink
Ruiz Property Page 6 of 7 <br /> Our Project Number: E07129A <br /> August 1, 2007 <br /> 3.5 Current Off-Site Sources of Contamination <br /> No above- or below-ground on-site potential or known sources of contamination were identified <br /> from current uses of the surrounding properties, except for the following: <br /> • There is a current a SLICcase located northwest of the property. <br /> ' 4.0 EVALUATION OF IDENTIFIED CONTAMINATION SOURCES <br /> i One cleanup and/or remediation case has been identified within one-quarter mile of the subject <br /> w property. Marley Cooling Tower Company, located approximately one-eight mile northwest of <br /> the subject property, has contaminated groundwater in the area with total chromium and (21 <br /> hexavalent chromium. However, based on the groundwater flow direction and current <br /> monitoring results, it does not appear that the subject property has been impacted at this time. <br /> F <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS <br /> F As the site is developed, any stained soil or sources of contamination identified should be / <br /> characterized and properly disposed in accordance with federal, state, and local regulations. <br /> 6.0 LIMITATIONS <br /> Hl� <br /> This report was compiled as a Surface and Subsurface Contamination Report for the subject <br /> property. This report contains information and data provided to NOA by several sources. NOA <br /> in no way warrants the accuracy or completeness of the information provided to this <br /> 0 investigation by those sources. <br /> It should be noted that when an environmental assessment is completed without sample <br /> F1 collection and quantitative analysis of soil and groundwater beneath the site, as in this study, <br /> no statement of scientific certainty can be made regarding latent subsurface conditions which <br /> may be the result of on-site or off-site sources. The findings and conclusions of this report are <br /> not scientific certainties, but rather, probabilities based on professional judgement concerning <br /> the significance of the data gathered during the course of this investigation. NOA is not able to <br /> represent that the site or adjoining land contains no hazardous waste, oil, underground storage <br /> F1 tanks, or other latent condition beyond that detected or observed by NOA during the Surface <br /> and Subsurface assessment. The possibility always exists for contaminants to migrate through <br /> surface water, air, or groundwater. <br /> Our office has not been provided with specific criteria for the development of this report other <br /> than a request to evaluate the property in question for possible problems related to toxic or <br /> hazardous agents, nor have we been directed to address any specific questions concerning the <br /> site. Should there be a need to conduct an investigation into a specific question not addressed <br /> in this report, contact our office immediately regarding your concerns. <br /> Fj <br /> n_ 902 Industrial Way•Lodi,CA 95240.209.367.3701 •Fax 09.369.4228 (D2007 Neil O.Anderson&Associates,Inc. <br />