Laserfiche WebLink
4 <br /> SOIL SUITABILITY STUDY <br /> FOR THE <br /> LISA WARD PROPERTY <br /> PARCEL 1 , A 43. 1 O ACRES NET PARCEL LOCATED ON THE <br /> EASTERLY SIDE OF THE "DIAMOND CREST' ESTATES" <br /> } SUBDIVISION AND EXTENDING THE FULL LENGTH OF THE <br /> EASTERLY SUBDISION BOUNDARY WITH ACCESS OFF A <br /> DIRT ROAD ON THE WESTERLY SIDE OF KASSON RAOD <br /> LOCATED SOUTHERLY OF THE "T" INTERSECTION OF <br /> AIRPORTWAY AND KASSON ROADS NEAR TRACY, <br /> f CALIFORNIA, IN SAN .JOAQUIN COUNTY ADF ES 8►�,��! <br /> i <br /> AP N: 255 - 34 - 01 cU � <br /> 3 11584 i <br /> April 4, 2002 <br /> IV <br /> Prepared By fie ! <br /> WALTER E. CURTIS <br /> CIVIL ENGINEER, C. E. NO. 1 1584 <br /> 418 MATTHEW PLAZA, LODI, CALIFORNIA 95240 <br /> PHONE: (209) 368 — 4159 <br /> PROJECT DESCRIPTION: To sell and develop a 43.10 net acres parcel,Parcel 1, of, <br /> the"Diamond Crest Subdivision", along with six(6)other parcels of about the same size <br /> in the subdivision that contains in excess of 240 acres, all as shown on the attached <br /> "Diamond Crest Estates Subdivision Map". <br /> TEST RESULTS: <br /> Parcel No. Test Hole No, Percolation Rate Min/Inch Minimum Usable <br /> r Shallow Test 3' Deep max Area(Square Feet <br /> 1 PH 1C 6.00 6,000 <br /> SOIL PROFILE: No water was encountered in excavating the Percolation or Soil <br /> Profile test holes on the subject parcel to a maximum depth of 10'00". Refer to the <br /> attached"Field Percolation Data Sheet", and"Parcel Map" as well as the text of:this <br /> report for the specific soil layers character and test hole location details. <br /> WELL WATER ANALYSIS: Well water testing and analysis isnot an integral part of � <br /> k this report. If any well water sampling and testing to determine needed chemical; <br /> concentrations are required,it is the responsibility of the property owner to provide and <br /> submit separate and apart from this report. v <br /> ` RECOMMENDATIONS: A 6,000 square feet minimum usable disposal area is <br /> �'-{ <br /> recommended for the 43.10 net acres parcel to accommodate a subsurface horizontal <br /> leach field. Also a.sump system installation is feasible. Ponding was noted on the gravel <br /> roads providing access to all of the aforementioned seven(7) parcels and together with <br /> the need to involve three (3) site selections to find appropriate soil to test and report on in <br /> this report shows that cardwl selection of an Tanned se tics stem site is needed. <br />