My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004762 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FIRST
>
9167
>
2600 - Land Use Program
>
PA-0300047
>
SU0004762 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:12 AM
Creation date
9/4/2019 6:33:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0004762
PE
2626
FACILITY_NAME
PA-0300047
STREET_NUMBER
9167
Direction
E
STREET_NAME
FIRST
STREET_TYPE
ST
City
VICTOR
APN
05109015
ENTERED_DATE
12/28/2004 12:00:00 AM
SITE_LOCATION
9167 E FIRST ST
RECEIVED_DATE
12/28/2004 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FIRST\9167\PA-0300047\SU0004762\SS STDY.PDF \MIGRATIONS\F\FIRST\9167\PA-0300047\SU0004762\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S = Sufficient <br /> I = Insufficient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> ❑ ❑ 6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> ❑✓ ❑ 62 The minimum number of shallow and deep percolation tests was performed for each parcel. <br /> ❑✓ ❑ 6.3 Description of the date,time and protocol used to prepare the lest hole,including depth and dimensions of hole, <br /> preparation of hole,and depth of water used to presoak(minimum 12 inches). <br /> ❑ ❑✓ 6.4 Description of the date,time and condition of the test hole after the 24-hour soak period(hole still intact,hole dry, <br /> depth to water remaining in hole,etc.) <br /> ❑✓ ❑ 6.5 The test conformed to SJC Policy EHD 02-02(correct depth,diameter,2"gravel,6"water refill,correct readings <br /> recorded). <br /> ❑✓ ❑ 6.6 Complete Percolation Test Form(including readings)was provided with REHS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> ✓❑ ❑ 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. <br /> ✓❑ ❑ 6.8 Discussion of percolation rates in relation to the type,size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> ❑ ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: Linda Turkatte, Lead Senior REHS Reviewed Date: 9/12/2003 <br /> EHD26-02-003 Page 2 of 3 <br /> 7/I4aW3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.