My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0008440 SSCRPT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRAZIER
>
22650
>
2600 - Land Use Program
>
PA-1000187
>
SU0008440 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:30 AM
Creation date
9/4/2019 6:39:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SU0008440
PE
2622
FACILITY_NAME
PA-1000187
STREET_NUMBER
22650
Direction
E
STREET_NAME
FRAZIER
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
06708001, 03
ENTERED_DATE
9/8/2010 12:00:00 AM
SITE_LOCATION
22650 E FRAZIER RD
RECEIVED_DATE
9/8/2010 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRAZIER\22650\PA-1000187\SU0008440\SSC RPT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> k: <br /> 3.2 Description of All Past On-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified at the Project Site: Past on-site potentials for <br /> contamination are low. The property has been used for agricultural purposes for more than Cz � <br /> 10 years. Historically there have been no underground storage tanks. The owner has no <br /> knowledge of above or below ground surfaces of contamination on the subject parcel. There is <br /> f one above ground portable fuel tank on subject parcel. <br /> A search for Use Reports and Permits did not yield any concerns for sources of contamination <br /> (see Appendix). All pesticides and fertilizers applied were done under Permit No. 3900351. <br /> Chemicals used were Carbaryl, Chloropicrin and Methyl Bromide to name a few (see Appendix <br /> for the entire inventory). <br /> 3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified at the Project Site: Presently there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence <br /> of buried containers, as well as no odors that would be associated with buried chemical tanks. 3, <br /> There is an above ground portable fuel tank on the site. On-site storm water is contained on <br /> site and dissipates through either percolation or evaporation. There is also some run-off to the <br /> river. Calaveras River is located on subject parcel. <br /> 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Past off-site potential �;- <br /> �' for contamination is low. The subject parcel is located in agricultural community. <br /> i <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified in the Area of the Project Site: Present <br /> off-site potential for contamination is low. There is no knowledge of below ground sources of <br /> contamination in the area of the project site that has or may impact the project site. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of Each Potential and/or Known Source of Contamination Identified for <br /> any Real and/or Potential Threat to Human Health and the Environment: The depth to <br /> potable water is 200 feet. Due to the depth, any pesticides, insecticides, and fertilizers used on <br /> the property in the past or present would have a minimal impact to the potable water. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are no chemical containers on this site; <br /> thus, the potential for contamination is low. As previously stated, any pesticides, insecticides, <br /> and fertilizers used on the site do not pose any significant potential for contamination to the <br /> � project site, and no mitigation measures are recommended. <br /> 3 <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.