Laserfiche WebLink
g. Allowable floor area <br /> h. Proposed floor area <br /> i. Occupant load based on the CBC <br /> j. Occupant load based on the CPC <br /> 6. The proposed conversion of an existing agricultural building to a storage building will <br /> constitute a change of occupancy.A change of occupancy will require a code analysis <br /> report and necessary plans prepared by an architect or engineer in accordance with the <br /> California Existing Building Code. The report and plans shall identify existing conditions, <br /> propose alterations necessary to bring the building in compliance with the current code and <br /> include the following: <br /> a. Description of proposed use <br /> b. Existing and proposed Occupancy Groups <br /> c. Type of construction <br /> d. Sprinklers(Yes or No) <br /> e. Number of stories <br /> f. Building height <br /> g. Allowable floor area <br /> h. Proposed floor area <br /> i. Occupant load based on the CBC for the new use <br /> j. Occupant load based on the CPC for the new use <br /> k. Risk Category analysis. (Agricultural Buildings are allowed to be constructed to Risk <br /> Category I,whereas other occupancies require Risk Category II or ll.) <br /> 7. Modifications to existing buildings are required to include upgrades related to disability <br /> access pursuant to the California Existing Building Code. Plans showing these upgrades <br /> must be prepared by a registered engineer or licensed architect and shall be submitted for <br /> review and approval prior to issuance of a building permit. <br /> 8. Accessible routes shall be provided per CBC§ 11 B-206.At least one accessible <br /> route shall be provided within the site from accessible parking spaces and accessible <br /> passenger loading zones;public streets and sidewalks;and public transportation stops to the <br /> accessible building or facility entrance they serve. Where more than one route is provided, <br /> all routes must be accessible. §11 B-206.2.1 <br /> 9. At least one accessible route shall connect accessible buildings, accessible facilities, <br /> accessible elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 10.At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines, which <br /> are otherwise connected by a circulation path.§11B-206.2.4 <br /> 11. Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are <br /> required for each phase of the project.These parking space(s)shall be located as close as <br /> possible to the primary entrance to the building. <br /> 12.Adequate sanitary facilities shall be provided for the facility,per the requirements of Chapter <br /> 4 of the California Plumbing Code. <br /> 13.This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> requirements of the California Code of Regulations,Title 22, Division 2, Chapter 2.7 <br /> 1810 E. Hazelton Avenue I Stockton, California 95205 1 (209)468-3121 1 www.sjgov.org/comnidev <br />