Laserfiche WebLink
Therefore,noise levels associated with these proposed facilities could exceed the MHMP's exterior noise <br /> standards for stationary noise sources if daytime or nighttime outdoor activity areas are located within 90 feet or <br /> 160 feet,respectively, of residential land uses.However,because noise generated by activities conducted in <br /> public parks,playgrounds,and school grounds,including school athletic events,is exempt from the MHMP's <br /> noise standards for non-transportation noise sources,this impact would be less than significant. <br /> Landscape Maintenance <br /> Equipment used for the maintenance of residential and non-residential landscaping, school,college,and park play <br /> fields,and vegetated road medians and berms includes lawnmowers and sprayers. Predicted noise levels <br /> associated with lawnmowers and sprayers are identified in Table 4.13-7.The noise of a mower generating 90 dBA <br /> L q would attenuate to the MHMP's daytime hourly threshold of 55 dBA and nighttime hourly threshold of 50 <br /> dBA L q at distances of 180 feet and 320 feet,respectively.However,landscape maintenance equipment typically <br /> would not operate in one place for an extended period.Lawn mowing and spraying, for instance, do not typically <br /> take place in any single area for more than a few minutes.Thus, operation of noise-generating landscaping <br /> equipment during daytime hours would not result in an exceedance of the MHMP's hourly Leq standards. <br /> Operation of landscape equipment during nighttime hours,however, may result in speech interference and <br /> increased sleep disruption to occupants of the nearby residences. A significant impact could occur. <br /> Table 4.13-7 <br /> Typical Landscape Maintenance Equipment (Lawnmower) Noise <br /> Equipment and Function Sound Level at Operator's Position Estimated Sound Level at 50 Feet <br /> Mower(Reelmaster 5000) 86 dBA,Ley 62 dBA,Leq <br /> ` Mower(Groundmaster 325D) 90 dBA Ley 66 dBA,Leq <br /> Multi Pro 1100 Sprayer 84 dBA,Leq 60 dBA,I. <br /> Notes:Sound levels at operator's position are based on manufacturers'specifications.Predicted sound levels at 50 feet assume a near- <br /> noise field of 3 feet and a 6-dBA reduction in noise levels per doubling of distance from the source. <br /> Source:EDAW 1997 <br /> Mitigation Measure 4.13-2: Nois"eneration of New Stationary-Source Noise <br /> The project applicants shall incorporate the measures identified below into the project design. <br /> Commercial, Office, and Industrial Uses <br /> Industrial and commercial land uses proposed as part of the College Park project shall be designed to ensure that <br /> outdoor equipment does not result in an exceedance of 55 dBA Leq during daytime hours(7:00 a.m.to 10:00 p.m.) <br /> or 50 dBA L.during nighttime hours(10:00 p.m. to 7:00 a.m.) at off-site noise-sensitive receptors. In addition, <br /> design and operational standards shall be established to minimize noise generated by loading dock activities from <br /> adversely affecting planned and existing off-site noise-sensitive land uses.Design and operational measures may <br /> include: <br /> ► Enclose outdoor noise-generating equipment and/or set back from the property line. <br /> ► Locate buildings and structures such that they shield off-site sensitive receptors from on-site noise sources, <br /> including loading dock activity. <br /> ► Enclose loading dock areas. <br /> College Park at Mountain House Speck Plan III Draft EIR EDAW <br /> San Joaquin County 4.13-19 Noise <br />