My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0005892 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOLLENBECK
>
2269
>
2600 - Land Use Program
>
PA-0600023
>
SU0005892 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:51 AM
Creation date
9/5/2019 11:18:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0005892
PE
2660
FACILITY_NAME
PA-0600023
STREET_NUMBER
2269
Direction
S
STREET_NAME
HOLLENBECK
STREET_TYPE
RD
City
STOCKTON
APN
18317010
ENTERED_DATE
1/24/2006 12:00:00 AM
SITE_LOCATION
2269 S HOLLENBECK RD
RECEIVED_DATE
1/24/2006 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOLLENBECK\2269\PA-0600023\SU0005892\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. <br /> ti July 28,2006 <br /> NOA Project Number: E05167B <br /> L Measurement of the water level during the percolation test was from a fixed reference point on the <br /> PVC casing using an electric well sounder with an depth accuracy of 1/100th foot. All tabulated <br /> values on the field data sheet (appendix) are in decimal feet. After water drop was observed, the <br /> Lholes were checked for refill. The refill level was approximately 0.5 ft (6 inches) of water above the <br /> bottom level of the percolation test hole. The readings were taken every 30 minutes for a period of <br /> four hours. <br /> b. 6.6 Percolation Test Forms and Results <br /> The completed percolation test form is included in the appendix of this report. <br /> A shallow percolation test is defined by the EHD as being between 36 and 42 inches in depth;a <br /> satisfactory percolation rate for a shallow test is less than or equal to 60 minutes per inch drop. A <br /> 6. deep percolation test is defined as being between 3.5 and 25 feet in depth;a satisfactory percolation <br /> rate for a deep test is less than or equal to 30 minutes per inch drop. One percolation test must <br /> ' demonstrate a satisfactory percolation rate within the proposed septic system disposal field of each <br /> parcel to utilize a standard septic system. Details of the percolation tests are summarized in Table 5. <br /> Table 5. <br /> Summary of Percolation Tests. <br /> Test No., Percolation Percolation Rate Test Comment <br /> Date Tested Test Depth(ft) (minutes/inch) Duration (see notes) <br /> P-1 Shallow 3.32 250 4 hours Failing percolation rate <br /> V P-1 Deep 19.43 9.26 4 hours Satisfacto ation care ercol <br /> Note: d satisfactory percolation rate fora"shallow"testis less than or equal to 60 minutes per inch.A satisfactory <br /> percolation rate for a"deep"test is less than or equal to 30 minutes per inch. <br /> 6a 6.7 Discussion of Percolation Test Results <br /> The soils within the sewage disposal areas of the site have demonstrated a satisfactory percolation <br /> 6. rate in accordance with the requirements of the EHD for the use of a standard septic system. <br /> i 6.8 Discussion of Septic System Sizing <br /> L <br /> Septic System Construction should follow the San Joaquin County On-Site Wastewater Disposal <br /> Standards where applicable. <br /> L 7.0 CONCLUSIONS <br /> In summary, satisfactory percolation rates of the soil were achieved in the proposed septic disposal <br /> Lareas of the Site. The septic disposal area of the proposed parcel appears suitable for a standard <br /> 8 <br /> L <br /> i <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.