My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS_FILE 2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
13975
>
2900 - Site Mitigation Program
>
PR0522057
>
FIELD DOCUMENTS_FILE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:41 AM
Creation date
9/5/2019 2:36:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
FileName_PostFix
FILE 2
RECORD_ID
PR0522057
PE
2950
FACILITY_ID
FA0015024
FACILITY_NAME
USA GASOLINE #3756
STREET_NUMBER
13975
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
APN
01908014
CURRENT_STATUS
01
SITE_LOCATION
13975 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 16 , 1987 p <br /> Beacon Station #675 - Lockeford, CA IAGS Job No. 87048-1 <br /> R <br /> WATER SAMPLING PROCEDURE <br /> Water samples were c°llected .from -the four monitoring wells for <br /> subjective .analysis by gently lowering a teflon bailer <br /> approximately halfway through the �air/water interface. The - <br /> samples were retrieved and inspected for. floating product, sheen, <br /> emulsion, and product odor. No 'sUbjective evidence of floating <br /> product, sheen, emulsion or <br /> #�► product odor-, was-=detected in. the <br /> samples from wells Mw-1through MW 4 . <br /> The wells were developed by air-` and water'-jetting and purged by <br /> Pumping approximately five well volumes of liquid. Following the - <br /> purge period, and after- well recovery tostatic water .level, <br /> water. samples were collected using-, a laboratory-cleaned teflon <br /> bailer. The- bailer .was- lowered through the air/water `interface - <br /> in order to .retrieve samples representative 'of the -formation <br /> water. <br /> i° <br /> F <br /> -- - - The samples were transferred -to laboratory:.clean 40 mlglass <br /> Volatile Organic Analysis (VOA). via-1s , made acidic by adding <br /> hydrochloric acids immediately sealed- with .teflon-lined caps , <br /> labeled, and-placed in. iced -storages for -transport to the` <br /> analytical laboratory for testing_, The Chain-of-Custody and <br /> �7., . ,. <br /> r <br /> A lied Geos stems. <br /> . <br /> pin Y t . ; <br />
The URL can be used to link to this page
Your browser does not support the video tag.