Laserfiche WebLink
File No. 20-1100-38 KLEINFELDER <br /> September 12, 1996 <br /> Groundwater was encountered at a depth of approximately 62 feet below existing ground surface <br /> in Boring B-2 at the time our borings were drilled. No free groundwater was encountered in the <br /> Teichert boring TRNA-5 which was drilled to a depth of 69 feet. According to Teichert, an <br /> existing onsite well drilled in 1992 had a groundwater depth of 88 feet. The adjacent Rose <br /> property is being mined to at least 70 feet and has not encountered groundwater. Based on these <br /> observations, the groundwater encountered in Boring B-2 is most likely a perched condition not <br /> representative of actual groundwater depths. We note that it is possible that groundwater <br /> conditions at the site may vary in the future because of variations in rainfall, irrigation, runoff, or <br /> ` other factors not apparent at the time our borings were drilled. <br /> The above is a general summary of the soil and groundwater conditions encountered in the <br /> borings drilled at the site. More detailed descriptions of the soils encountered in the borings are <br /> noted on the Logs of Borings, Appendix A, Plates A-3 and A-4. All soils have been classified <br /> according to the Unified Soil Classification System (USCS) which is described on Plate A-2 of <br /> Appendix A. <br /> VI. LABORATORY TESTING <br /> Laboratory tests were performed on selected samples obtained from the borings in order to <br /> evaluate the strength characteristics of the soils encountered. The tests performed consisted of <br /> Direct Shear tests. The results of these tests are noted on the Logs of Borings at the corresponding <br /> sample locations and test results are presented on Plates A-5 through A-7 of Appendix A. <br /> r <br /> VII SLOPE STABILITY ANALYSIS <br /> As in previous studies for other nearby quarry operations, we have relied on the performance of <br /> existing slopes and on strength tests performed on relatively undisturbed samples to evaluate input <br /> values for our computer analyses. An example of existing slopes studied is an approximately 60- <br /> foot high, near-vertical (78 degree) slope at Teichert's Tracy facility, west of the site. Laboratory <br /> strength tests have not been performed on any of the gravelly materials from the Traina site, as <br /> explained in section IV of this report and for this reason, our analyses are conditional on tests <br /> being performed during initial excavation of the quarry to confirm strength parameters and soil <br /> ` type. <br /> The slope stability analyses were performed using the computer programs SLOPE/W. SLOPE/W <br /> uses the limit equilibrium theory to compute the factor of safety of earth and rock slopes using the <br /> following methods: Ordinary or Fellenius, Bishop's Simplified, Janbu's Simplified, Spencer, <br /> Morgenstem-Price, Corps of Engineers, Lowe-Karafiath, General Limit Equilibrium, and Finite <br /> Element Stress. Based primarily on the soil conditions and our experience with large existing cuts <br /> in similar materials, we anticipate that a wedge or partially circular type failure would be <br /> appropriate. In order to evaluate other possibilities, we have also evaluated numerous circular <br /> failure conditions as well. <br /> 20-1100-381MR960198 Page 3 of 6 01996,Kleinfelder, Inc. <br />