Laserfiche WebLink
The above note,together with the owner consenting to the preparation and filing of the <br /> map, gives constructive notice to title companies, future property buyers and the public of <br /> the requirement to provide a private irrigation easement as well as its size and location. <br /> b. Obtain a structure permit for new service structure connections to District <br /> facilities which are necessary to provide service to the new parcels. <br /> c. The design strength and diameter of the proposed private pipelines andstructures <br /> shall be adequate to handle standard delivery heads or flows for that area. <br /> If a recorded map is not required,the above stated conditions shall be recorded in <br /> conjunction with the recording of deeds for the newly created parcels. <br /> 3. The owner shall grant easements of sufficient width for all District facilities which may <br /> exist on subject property to serve as a replacement for any prescriptive and/or unrecorded <br /> easements that are present. All existing recorded or newly dedicated District easements <br /> shall be shown and identified on the survey map prior to its recording. If a map is not <br /> required, easements shall be recorded by separate instrument concurrent with the <br /> recordation of new deeds. <br /> 4. Owner shall obtain an Encroachment Permit from District for fencing or any other <br /> proposed encroachments of District easements resulting from the proposed parcel split. <br /> Owner shall provide District with unrestricted access to its pipeline and control <br /> structures. <br /> 5. If a proposed homesite or building area is lower than adjacent irrigated property, a <br /> permanent berm or ditch will need to be constructed around the homesite parcel or <br /> building site, to prevent accidental flooding from irrigation water. Property owner shall <br /> either verify field elevations or submit a written statement to District indicating that <br /> property in question is not subject to flooding from adjacent irrigated property or <br /> pipelines. Likewise, owner shall provide the District with a written statement or <br /> explanation if any of the above stated conditions do not pertain to the situation involving <br /> the proposed minor subdivision. <br /> 6. A copy of the survey map, if required, shall be provided to the District Engineering <br /> Department for review to ensure that the above conditions have been satisfied. <br /> If you have any questions,please contact me in the Engineering Department at(209) 249-4617. <br /> Very truly <br /> yy yours, <br /> Sam Bologna <br /> Engineering Department Manager <br /> P.O. Boa 747, Ripon, CA 95366-0747 (Mailing) <br /> 11011 E. Highway 120, Manteca, CA 95336-9750 <br /> (209) 249-4600 <br />