SU0004688 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
12833
>
2600 - Land Use Program
>
PA-0400646
>
SU0004688 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:06 AM
Creation date
9/6/2019 10:05:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0004688
PE
2626
FACILITY_NAME
PA-0400646
STREET_NUMBER
12833
Direction
S
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
LATHROP
APN
19123007
ENTERED_DATE
11/3/2004 12:00:00 AM
SITE_LOCATION
12833 S MANTHEY RD
RECEIVED_DATE
11/2/2004 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MANTHEY\12833\PA-0400646\SU0004688\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ratubes:4" PVC pipe extending to soil/effluent interface with 4" riser extending above the grass <br /> east 0.5 foot,with a screw type cap. Both soil sampling tubes must be placed in proximity to <br /> e. <br /> D. SEPTIC SYSTEM OPERATIONALPARAMETERS AND COMPONENTS - <br /> WEST LEACHFIELD (W.L.F.) AREA TO SERVE EXISTING OFFICE TRAILERS <br /> SSS§3.7 The pressurized filter bed system for the Office Trailers will be comparable to the filter bed <br /> disposal area for the new Office Building. An overview of the septic system operation is as follows: Influent <br /> wastes from both Office Trailers will gravity into a dual compartment 2,000 gallon septic tank. The second <br /> compartment will be the pump chamber with a duplex pump system within a Biotube filter vault to <br /> pressurize the single filter bed. <br /> W.L.F. SEPTIC TANK <br /> The following calculations demonstrate septic tank capacity as was calculated for the E.L.F. above with a <br /> pump-out interval of one year. <br /> Septic Tank Capacity Based on Pumn-out Interval of One Year: <br /> Recommended tank capacity for a potential pump-out interval of one year after complete build-out: <br /> 1.6(pump-out interval factor)(QAIE)x Peaking Factor(PF=2.5)= 1.6(150 gaWday)x 2.5 =600 gals. <br /> Total septic tank capacity= one -2,000 gallon tanks. <br /> Detention Time: <br /> Detention Time=2,000 gal total tank capacity x 0.70(30%volume lost to sludge/scum accumulation) <br /> 2.5 (Peaking factor)x 150 gals/day(ADF) <br /> Detention Time=3.7 days. The minimum acceptable detention time is 1.0 day. <br /> Caution must be given to the buoyancy potential all of the tanks, due to the potentially high groundwater <br /> table. Contents of the tank should never be entirely pumped out. <br /> W.L.F.PRESSURIZED FILTER BED SIZING CALCULATIONS <br /> Base Tank Capacity= 1,200 gal. ADF= 150 gpd <br /> Leachline Equivalent Requirement= 1,200 gallons BTC+ 150 ADF x 0.225 Silt Soil Factor(SF)=304 <br /> lineal feet of leachline(LFLL). 304 x 3 (Sandy Silt Soil -Filter Bed Soil Factor)_ <br /> 911 sq.ft. filter bed area required. <br /> Proposed Filter Bed Area(Single Bed Only)=91 ft N-S long x 10 feet E-W wide = <br /> 910 sq.ft to be installed: <br /> 100% Reserve Replacement Area: This area is denoted on the Site Plans and is situated directly to west of <br /> the primary disposal field. <br /> 19 <br /> Chesney Consulting <br />
The URL can be used to link to this page
Your browser does not support the video tag.