My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0000017 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICKE GROVE
>
10979
>
2600 - Land Use Program
>
MS-01-24
>
SU0000017 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:27:33 AM
Creation date
9/6/2019 10:10:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0000017
PE
2622
FACILITY_NAME
MS-01-24
STREET_NUMBER
10979
Direction
N
STREET_NAME
MICKE GROVE
STREET_TYPE
RD
City
LODI
Zip
95240
ENTERED_DATE
8/8/2001 12:00:00 AM
SITE_LOCATION
10979 N MICKE GROVE RD
RECEIVED_DATE
7/10/2001 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MICKE GROVE\10979\MS-01-24\SU0000017\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> A n <br /> Soil Suitability Study***MS-01-24*** APN: 059-210-37***2 Parcels,Parcel A=5A3 Acres and <br /> Parcel B-5.00 Acres***Total=10.03 Acres <br /> The shallow an deep percolation tests conducted were performed in accordance <br /> with the percolation test procedures outlined in the "Manual Of Septic Tank Practice" <br /> published by the Department Of Health Education And Welfare and the requirements of <br /> the San Joaquin County Public Heath Service, Environmental Health Division. <br /> The results of both the shallow and deep percolation tests on Parcels A and B are <br /> as follows: <br /> TEST RESULTS: <br /> Parcel No. Test Hole No. Percolation Rate (Mn./Inch) Minimum Usable) <br /> Shallow Test(3')Deep Test(25' Max} Area(Square Feet) <br /> A PA 30 10,000 <br /> B PB4 Failed(>60) No recommendation <br /> B PB5 2.4 12,000 sq. ft. +Pits <br /> RECOMMENDATIONS: A 10,000 square feet minimum usable disposal area is <br /> recommended for Parcel A to accommodate a subsurface horizontal leach field. A <br /> 12,000 square feet minimum usable disposal area plus pits is recommended for Parcel B. <br /> WELL WATER ANALYSIS: <br /> Well water was tested for Dibromochloropropane (DBCP) and Nitrate (NO3) <br /> concentrations. The results of this testing is contained in the attached Far West <br /> Laboratories,Inc. letter, dated August 29, 2001 and by inclusion in this report is made an <br /> integral part of this study. The results of the Far West Laboratories, Inc. tests on DBCP <br /> and nitrates are summarized as follows: <br /> Chemical Constituents <br /> Dibromochloropropane (DBCP.) lua/L1 4Nitrate(NO3�m <br /> SND-"(Not etected) `6t1: <br /> The Nitrate (NO3)and Dibromochloropropane (DBCP) concentrations for the <br /> well water sampled are well within the State's standards for safe public drinking water <br /> established at 45 mg/L and 0.2 ug/L for Nitrates (NO3) and Dibromochloropropane <br /> (DBCP)respectively. <br /> ENGINEER'S STATEMENT: <br /> Septic systems of the types proposed can be installed and their construction is not <br /> expected to impact groundwater or cause other health hazards. <br /> Walter E. urtis <br /> Civil Engineer, C.E. # 11584 <br /> Attachments: "Parcel Map" (1), "Test Hole Location Map"(1), Field Percolation Data <br /> Sheet(2), Far West Laboratories, Inc., 08/29/01 reporting letter,and <br /> Masellis Drilling"Geotechnical Log", dated 07/25/01 <br /> Earl Sellers, 10979 North Micke Grove Road,Lodi, California 95240;(209)478-5760,(209)610-5602 <br /> • fi <br />
The URL can be used to link to this page
Your browser does not support the video tag.