Laserfiche WebLink
street improvements does not relieve the initial developer from designing and constructing <br /> drainage facilities to serve the exempted improvement area. <br /> 55. If the property shown on the Tentative Map is to be developed in phases, then a subdivision <br /> agreement and appropriate bonding shall be executed between the MHCSD and the <br /> developer for each phase prior to the approval of the Final Map. <br /> 56. If the land covered by the Tentative Map is to be developed in phases, then the boundary of <br /> each phase shall be determined by the following access requirements: <br /> A. Two points of access shall be extended to streets having a classification of residential <br /> collector or higher. <br /> B. If a phase boundary is to parallel the alignment of an in-tract street, then the <br /> boundary shall be along the rear line of the lots facing the street. Boundary lines along <br /> the centerline or edge of a right-of-way line of a street shall not be allowed, except <br /> when specifically approved in writing by the General Manager of the MHCSD. <br /> C. Prior to the beginning of the final design of the subdivision, the MHCSD General Manager <br /> shall consult with Tracy Fire regarding emergency access to the proposed development. <br /> Any requirements for emergency access shall be approved by MHCSD. <br /> 57. Except where allowed otherwise by the MHCSD, the grading of the project shall be such that <br /> all storm water runoff shall drain to public streets, public alleys, Mountain House Creek, or <br /> drainage facilities within easements for storm drainage purposes. Runoff across property <br /> lines to adjacent private property(not including alleys that have storm drainage facilities <br /> maintained by the MHCSD or a homeowner's association)shall not be allowed. <br /> 58. The minimum arterial improvements as described herein shall be constructed as necessary <br /> to serve the proposed development or phases of development as determined by MHCSD. <br /> 59. All residential buildings shall be wired per specifications in the"Low Voltage Construction <br /> Pre-wire Guidelines"and other specifications provided by the MHCSD. <br /> 60. Sound walls, meeting the design requirements contained in the MHCSD Design Guidelines, <br /> shall be installed on arterial streets (except for Central Parkway)when the adjacent <br /> development(or phased development) has abutting lots. The length of the sound wall shall <br /> match the total length of the lots abutting the arterial street plus an additional length that will <br /> close a gap to a previously constructed wall not more than 200 feet away. <br /> 61. The sound walls shall be constructed consistent with the MHCSD Design Manual, the Master <br /> Plan and as shown on the preliminary sound wall plans. The noise barrier may consist of a <br /> wall, berm, or combination thereof the exact location, height and character of the sound <br /> barrier shall be determined by a noise consultant approved by the County and the MHCSD. <br /> The sound barrier shall reduce outdoor noise levels at the center of backyards of proposed <br /> adjacent single-family residences to below 65 dBA LdWCNEL and as close to 60 dBA <br /> LdWCNEL as feasible. <br /> 62. The developers of SP III shall dedicate the necessary R/W to widen Grant Line Road to its <br /> ultimate width and construct the noise barrier at its ultimate location as specified by the <br /> General Manager of the MHCSD. <br /> 63. Except when the MHCSD General Manager species otherwise,when a sound wall is <br /> installed on an arterial street, the adjacent street edge landscaping, sidewalk, and street curb <br /> &gutter shall also be installed. <br /> 23 <br />