SU0005047 SSCRPT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
975
>
2600 - Land Use Program
>
PA-0500280
>
SU0005047 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:26 AM
Creation date
9/6/2019 10:27:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SU0005047
PE
2622
FACILITY_NAME
PA-0500280
STREET_NUMBER
975
Direction
S
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
STOCKTON
APN
10323018
ENTERED_DATE
5/16/2005 12:00:00 AM
SITE_LOCATION
975 S JACK TONE RD
RECEIVED_DATE
5/13/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\J\JACK TONE\975\PA-0500280\SU0005047\SSC RPT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.3 Description of all current on-site potential and/or known above and below ground <br /> � <br /> / sources of contam�ation identified at the project site: Presently, there are no underground <br /> ,"Ike storage tanks onte property and visual inspection did not produce any evidence of burie �,, <br /> containers, as well as no odors that would be associated with buried chemical tanks. There are no <br /> fertilizer tanks above ground. There is an existing propane tank near the home. Potter Creek lies <br /> along the south boundary of the parcel (see tentative map). <br /> 3.4 Description of all past off-site potential and/or known above and below ground sources <br /> of contamination identified in the area of the project site: Past off-site potential for <br /> contamination is the proximity to Potter Creek. Other sources of potential contamination is the <br /> surrounding orchards and the chemicals used in their farming operation. There is no knowledge <br /> of below ground sources of contamination in the area of the project site that has or may impact <br /> the project site. <br /> 3.5 Description of all present off-site potential and/or known above and below ground <br /> sources of contamination identified in the area of the project site: Present off-site potential <br /> for contamination is the proximity to Potter Creek. Other sources of potential contamination is <br /> the surrounding orchards and the chemicals used in their farming operation. There is no <br /> knowledge of below ground sources of contamination in the area of the project site that has or <br /> may impact the project site. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of each potential and/or known source of contamination identified for any <br /> real and/or potential threat to human health and the environment: The depth to ground <br /> water in this area is approximately 90 feet. Due to this depth, any pesticides, insecticides, and <br /> fertilizers used on the property in the past or present would have a minimal impact to the ground <br /> water. The use of approved best management practices for the containment of soil or any <br /> contaminates by straw waddles around the construction site and other practices to reduce the <br /> introduction of any dirt or contaminates into the storm runoff system will be required at the time <br /> of any fixture construction per County Building Department. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the above evaluation: The aforementioned farming practices creates the only <br /> potential for contamination. In the case of severe flooding,Potter Creek could potentially be a <br /> source of contamination as well. The close proximity to Jack Tone Road could be a concern. <br /> However with the drainage of water away from the highway and the fact that the water from <br /> Jack Tone Road is not retained on the subject property, the potential for contamination would be <br /> low, and no mitigation measures are recommended at this time. <br /> 2 <br /> 0031 MContaminatlon Report 022706 <br />