Laserfiche WebLink
KLEINFELDER <br /> LFour pole-mounted transformers are located along the western edge of the site (Photos 8 and <br /> 9, Plate 4, Appendix A). The transformers appeared in good condition with no evidence of <br /> Lleaks or staining on the ground surface below. It is unknown if the transformers contain <br /> PCBs. <br /> I <br /> 8.1.3. Off-Site Findings <br /> L • A debris pile was located north of the site. The pile contained limbs from the vineyards and <br /> pieces of lumber. The debris pile is not expected to have an adverse impact on the site. <br /> L <br /> 8.2. DEVIATIONS <br /> i <br /> No significant deviations were made from the ASTM E 1527-00 practice. No other "non-scope" <br /> considerations, such as asbestos-containing materials, radon, lead-based paint, lead in drinking <br /> 6. water, wetlands, regulatory compliance, cultural and historic resources, industrial hygiene, health <br /> and safety, ecological resources, endangered species, indoor air quality and high voltage <br /> powerlines were considered for this report. <br /> 8.3. CONCLUSIONS AND RECOMMENDATIONS <br /> Kleinfelder has performed a Phase I Environmental Site Assessment in conformance with the <br /> scope and limitations of ASTM Practice E 1527 of the approximately 80-acre property located <br /> west of Elliott Road and north of Jahant Road in Acampo, California. <br /> L <br /> In summary, this assessment has revealed evidence of possible recognized environmental <br /> L conditions in connection with the site. <br /> L • On properties with a history of agricultural use, such as the project site, underground <br /> pipelines may exist. It was common for said pipelines to contain asbestos (e.g. "Transite" <br /> Lpipe). Subsurface exploration is not a part of a typical Phase 1 Environmental Site <br /> Assessment scope of work. In the event that any subsurface structures are encountered <br /> during site development or excavation on site, care should be exercised in evaluating whether <br /> or not the subsurface structures contain asbestos. If they contain asbestos, they should be <br /> removed, handled, transported and disposed of in accordance with Federal, State and local <br /> L laws and regulations. Additionally, if suspect materials are encountered, the signatories of <br /> this report should be notified immediately. <br /> i <br /> 4 20-4019-08.P01/2011R1314 Page 26 of 28 <br /> Copyright 2001 Kleinfelder,Inc. October 26,2001 <br />