Laserfiche WebLink
recoup all or a portion of any over sizing costs, the developer may request the MHCSD to <br /> process a reimbursement agreement pursuant to a MARA. <br /> d. When public utilities are to be located outside public rights-of-way but within the Tentative <br /> Map boundary, the developer shall provide public utility easements for these utilities. The <br /> easements shall be shown on all Final Maps and Parcel Maps. <br /> e. Prior to the submittal of improvement plans for the development, the developer shall <br /> submit to the MHCSD composite schematic plans for intract storm drains, sanitary <br /> sewers, and water distribution facilities. <br /> f. Electrical transformers within residential Neighborhoods shall be in underground vaults, <br /> subject to MHCSD and Modesto Irrigation District (MID) requirements. The developer <br /> shall pay for any incremental costs relating to undergrounding transformers not paid for <br /> by MID. <br /> g. The developer shall fund, design and construct the required storm drainage system in <br /> accordance with the requirements of the Storm Water Master Plan Update and the <br /> MHCSD's Standards and Specifications to serve the Tracts unless otherwise required or <br /> approved by the General Manager of the MHCSD. <br /> h. The applicant shall construct catch basin filters and/or other source control Best <br /> Management Practices (BMPs)for urban runoff from Tracts as determined by the <br /> MHCSD. <br /> i. MHCSD approved catch basin insert filters must be installed, intract and on the <br /> arterials abutting the project, prior to construction. <br /> ii. All intract filters must be maintained by the HOA. <br /> 50. Wastewater Treatment Plant: <br /> a. Under the direction of the MHCSD, the applicant shall fund, design and construct a <br /> phased expansion of the wastewater treatment plant (WWTP)of sufficient capacity to <br /> serve this Tentative Map prior to reaching existing treatment plant capacity as determined <br /> by the MHCSD. <br /> b. The developer shall extend existing pipelines to the project site as shown on the Master <br /> Sanitary Sewer Plan. <br /> 51. Water Treatment Plant: Under the direction of the MHCSD, the applicant shall fund, design and <br /> construct a phased expansion of the water treatment plant (WTP), if applicable, to provide the <br /> capacity needed to serve the project prior to reaching existing treatment plant capacity. Timing: <br /> prior to Issuance of the first building permit <br /> 52. Traffic—Calming Circles: All proposed traffic circles shall conform to MHCSD traffic circle <br /> standards. <br /> 53. The applicant shall comply with the requirements of the Transportation Demand Management <br /> and Transit Plan (Hoyt, 1997) as administered by the MHCSD. Timing: ongoing. <br /> 54. Construction Emissions: The applicant shall implement the following: Regulation VIII Control <br /> Measures of the SJVAPCD and applicable measures of the SJVAPCD Guide for Assessing and <br /> Mitigating Air Quality Impacts. Timing: Note on improvement plans approved by the MHCSD for <br /> Tracts. <br /> 55. Construction-Related Erosion: The applicant and/or contractor shall comply with applicable <br /> NPDES General Construction Activities Storm Water Permit requirements established by the <br /> Clean Water Act. Pursuant to the NPDES Storm Water Program, an application for coverage <br /> Resolution Template 01/2017 <br />