Laserfiche WebLink
incorporate mosquito prevention best management practices for managed wetlands, such as <br /> those authored by the California Department of Fish and Game. <br /> 3. The developer shall prevent the creation of mosquito breeding habitat in all stormwater BMPs by <br /> incorporating mosquito prevention techniques authored by the California Department of Health <br /> Services. <br /> X. San Joaquin County Public Works — SB 5 Compliance (Staff Contact Fritz <br /> Buchman, 209-468-3101) <br /> 1. The project is entirely outside of the 200-year ULOP footprint identified in the PBI / R&F <br /> Engineerinq memo dated March 9,2022 (or subsequent updates) <br /> a. For a DA, discretionary entitlement increasing occupancy or tentative map: Make a <br /> finding in the project approval document that: Flood management facilities protect the <br /> project to the urban level of flood protection. <br /> b. For a building permit for a new residence: Document in the permit file that the residence <br /> is outside the 200-year ULOP floodplain <br /> 2. The proiect is partially or entirely within the 200-year ULOP footprint identified in the PBI/ <br /> R&F memo (or subsequent updates) <br /> a. For a DA, discretionary entitlement increasing occupancy or tentative map: Condition the <br /> proiect : Finish floor/ lot pad elevations shall be no more than three feet below the 200- <br /> year ULOP water surface elevation.: and make a finding in the proiect approval document <br /> that: The County has imposed conditions that will protect the proiect to the urban level of <br /> flood protection. <br /> b. For a building permit for a new residence: Review the certified grading plan in the <br /> subdivision improvement plans and verify/document in the permit file that the lot pad / <br /> finish floor elevation is no greater than three feet below the 200-year ULOP water surface <br /> elevation identified in the PBI / R&F memo (or subsequent updates) . <br /> Note that for the current 100-year and 200-year elevations in MH, the requirement for lot pad /finish floor <br /> elevations to be no more than three feet below the current 200-year water surface will automatically <br /> satisfy the satisfy the Development Title's FEMA 100-year plus one foot requirement. <br /> SB 5 does not apply to by-right non-residential projects or for residential building permits that do not result <br /> in construction of a new residence (remodel, water heater permits, etc.). <br /> Resolution Template 01/2017 <br />