Laserfiche WebLink
9. Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. These parking space(s)shall be located as close as <br /> possible to the primary entrance to the building. <br /> 10. Pursuant to Table 4-3 of the California Plumbing Code, toilet facilities shall be accessible to <br /> employees at all times, should not be more that 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs. The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas. <br /> Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 of <br /> the California Plumbing Code. <br /> 11. If high piled combustible storage is to be used in a building, an automatic fire sprinkler system will <br /> be required. <br /> 12. This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> requirements of the California Code of Regulations, Title 23, Division 2, Chapter 2.7. <br /> j. CALIFORNIA FIRE CODE: The following California Fire Code (CFC) will be applicable to the <br /> proposed project. The following conditions shall be addressed prior to submittal of a building <br /> permit application to the Building Inspection Division. <br /> 1) CFC 507 Fire Protection Water Supply - Fire flow and hydrants shall be provided for the <br /> proposed project by the use of: CFC Appendix B. <br /> 2) If Fire Protection Systems are required they shall be installed according to the CFC, Chapter 9 <br /> and the appropriate standards and guides adopted in Chapter 35 of the California Building Code <br /> and the California Electrical Code. <br /> 3) CFC, Section 503 Fire Apparatus Access Road - Shall be provided as required by this section. <br /> 503.1.2-A secondary access may be required. <br /> 4) CFC, Section 906 Portable Fire Extinguishers— Provide portable fire extinguishers as required <br /> by this section. <br /> 5) CFC, Section 506 Key Box - A Knox® Box shall be installed according to the local fire <br /> departments instructions. Make application for the key box at the fire district having jurisdiction <br /> of this project. If there is an electronically controlled access gate at this site a Knox® key switch <br /> will also be required. <br /> 6) CFC, Section 5001.3.3.1 Properties of Hazardous Materials — A complete list of hazardous <br /> materials used and or stored at this site shall be provided. <br /> 7) A complete review at building permit submittal will require compliance with applicable codes and <br /> ordinances. <br /> 8) CFC, Section 105 Permits: Operational Permit(s)may be required prior to occupancy. <br /> 2. DEPARTMENT OF PUBLIC WORKS(Seethe attached memo dated February 13, 2017) <br /> 3. ENVIRONMENTAL HEALTH DEPARTMENT(Seethe attached memo dated February 3, 2017) <br /> PA-1600200 (SA) Conditions of Approval 4 <br />