My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004094
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KOSTER
>
36736
>
2600 - Land Use Program
>
QX-01-0002
>
SU0004094
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2020 1:02:10 PM
Creation date
9/6/2019 10:43:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0004094
FACILITY_NAME
QX-01-0002
STREET_NUMBER
36736
Direction
S
STREET_NAME
KOSTER
STREET_TYPE
RD
City
TRACY
ENTERED_DATE
5/12/2004 12:00:00 AM
SITE_LOCATION
36736 S KOSTER RD
RECEIVED_DATE
1/8/2002 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\K\KOSTER\36736\QX-01-02_PA-0200065\SU0004094\EIR 2004.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2073
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.11 Hazards and Hazardous Materials <br /> lr <br /> A SPCC will be required to be prepared for the site in accordance with 40 CFR 112, and the State <br /> Aboveground Petroleum Storage Act program. The SPCC Plan will address the liquid petroleum <br /> products that are stored and used at the site,and provide the procedures for the prevention of <br /> discharge of the products into any on-site waters. As required by the RWQCB, the tanks would <br /> have secondary containment consisting of a concrete berm that will have a capacity to contain <br /> 110 percent of the tank size. <br /> The Mine Safety Orders, Section 6982,Materials Storage and Handling, would be complied with <br /> for all hazardous materials and compressed gas cylinders at the project site. The regulations <br /> r <br /> require the following: <br /> • Materials shall be stored in conformance with the Housekeeping and Maintenance <br /> Standards of the General Industry Safety Orders. <br /> • Hazardous materials shall be stored and handled in conformance with Hot, <br /> Flammable, Poisonous,Corrosive, and Irritant Substances Standards of the General <br /> Industry Safety Orders. <br /> • Hazardous materials shall be labeled in conformance with the Labeling of Injurious <br /> Substances Standards of the General Industry Safety Orders. <br /> r <br /> • Compressed and liquid gas cylinders shall be stored and/or secured in conformance <br /> with the General Industry Safety Orders. <br /> • Valves on compressed gas cylinders shall be protected by covers when being <br /> transported or stored,and by a safe location when the cylinders are in use. <br /> Mitigation Measure: None required. <br /> Impact 4.11.4: Exposure of the existing and future residents near the project area to <br /> •• potentially high levels of nuisance and disease vectoring mosquitoes from the addition of silt <br /> ponds and mining pits that could contain storm water on the project site would be a <br /> significant health hazard. Mosquitoes are vectors of diseases such as malaria,encephalitis, <br /> .. west Nile virus,and canine heartworm disease. (Potentially significant) <br /> Mitigation Measure <br /> Measure 4.11.4: The silt ponds and the mining pits proposed as a part of the project <br /> should be properly designed and maintained so that they do not breed mosquitoes. The <br /> design and maintenance of the basins should be done in consultation with the San Joaquin <br /> County Mosquito Abatement District and the East Side Mosquito Abatement District in <br /> Stanislaus County. <br /> r <br /> Impact Significance After Mitigation: Less than significant. <br /> RMC Pacific Vernalis Quarry Mining and Reclamation Project -15 ESA/203015 <br /> Draft Environmental Impact Report May 2006 <br />
The URL can be used to link to this page
Your browser does not support the video tag.