Laserfiche WebLink
SUMMARY <br /> A standard septic system should function satisfactorily in the type of soil observed in the <br /> test holes, when the system is installed in accordance with current standards of San Joaquin <br /> County, Environmental Health Department.A standard structurally sound and waterproof, <br /> 1600 gallon, two compartment tank*is recommended The 4"Biotube Effluent Filter by OSI, <br /> or equal, is recommended. The use of this filter type, adds a measure of protection for the <br /> leach field <br /> No traffic should cross the leach field area. Compaction of the soil in the leach field area <br /> reduces the evaporation rate. <br /> *The most efficient septic tank is the Meander Tank by Willamette Grayston Inc., of Eugene, <br /> OR. The design provides aabout 4 times the normal travel time in the tank. This increases <br /> the settlement of solids and provides for a higher grade of effluent to the leach field <br /> The proposed use of the subdivision for SFR's when developed in accordance with San <br /> Joaquin County Standards and Ordinances is not expected to cause any health hazard End <br /> of Narative <br /> 4. <br />