Laserfiche WebLink
7followingt of flow determinations describe the rationale for arriving at a maximum daily effluent <br /> he Windmill Winery project: <br /> Joaquin County Sewage Standards assign 15 gallons per person for a project with events of <br /> However, it is unknown as to how many people may attend any given event. <br /> 2. The number of bathroom fixtures(toilets) is proposed to be one men's and one women's for the <br /> winery. The Sewage Standards assign 150 gallons per toilet fixture (employee/public use)for a <br /> total of 300 gpd. Residential flows are generally assigned 70 gallons/day/person. <br /> 3. The total number of parking spaces for the Windmill Winery will be 13 spaces in the front and 23 in <br /> the back, for a total of 36. Assigning 15 gallons for each parking space will provide a theoretical 5 <br /> gallons for each vehicle with three passengers. <br /> Based upon these criteria referenced above,the maximum "average daily flow"(ADF) should be <br /> based upon the total number of parking spaces with 15 gallons assigned to each stall: <br /> 36 parking stalls x 15 gals assigned=540 gallons per day(gpd). <br /> It is acceptable to EHD to incorporate the residential ADF into this 540 gpd from the two bedroom, <br /> two bath house. <br /> Primary and 100% Replacement Filter Bed Area <br /> The filter bed area is calculated in the procedure described in Section 8.7 of the San Joaquin County Sewage <br /> Standards and EHD Document 42-01-004: <br /> Calculation Requirements for Co 'al S tic Systems: <br /> Base Tank Capacity(BTC)= 21, 00 Pal <br /> Lineal Feet of Leachline (LFLL)= 1,200 BTC+540 ADF x 0.225 Soil Factor based on a loam soil at 24 <br /> inches below grade where the soil-effluent interface will occur=400 LFLL <br /> Filter Bed Area=400 LFLL x 3 (Loam Soil Factor) = 1,200 square feet. The primary filter bed area is <br /> proposed to be rectangular in area: 20 ft wide x 60 ft long= 1,200 sq. ft. The manifold is to be center feed as <br /> depicted on the Site Schematic. {} <br /> The filter bed area may also correspond with the percolation test results. As referenced above, the�� <br /> application rate correlated with the 24 inch deep shallow perc test results of 9.7 mpi translate to an �( <br /> application rate of 0.857 gals/ft/day. Using theof 5 e find: 540 gpd_0.857 <br /> gals/ft2/day =630 sq. ft. Therefore, the filter bed size'df1,200 sq.yt. is adequate with a safety factor <br /> 0 2�ased on the test results obtained. The-100%replace is direcou a primary <br /> filter bed, in an area designated for reserve parking, and is also to consist o ,200 sq. ft. <br /> The primary filter bed, and potentially, 100% replacement area filter bed will consist f Quick <br /> Four Standard Infiltrator Chambers® Si inch spacers must be used in-between the chaThe <br /> pressure laterals will be at the tops of1hekhambers with the effluent trickling down over the louvers. <br /> A washed sand must be placed on top of the excavated filter bed at the soil-effluent interface prior to <br /> Infiltrator Chamber emplacement. Backfill soil over the chambers should consist of a sandy loam <br /> material, with four to six inches of cover soil material over the chambers. A grass-type lawn may be <br /> planted over the disposal area so that the plant roots can evapotranspire effluent from the louvers <br /> during favorable times of the year. <br /> Page -8- <br /> Chesney Consulting <br />