My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004992 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
18424
>
2600 - Land Use Program
>
PA-0500198
>
SU0004992 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:23 AM
Creation date
9/6/2019 11:05:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0004992
PE
2690
FACILITY_NAME
PA-0500198
STREET_NUMBER
18424
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
ESCALON
APN
20507035
ENTERED_DATE
4/20/2005 12:00:00 AM
SITE_LOCATION
18424 E LOUISE AVE
RECEIVED_DATE
4/19/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\18424\PA-0500198\SU0004992\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fexisting <br /> ion testing was conducted on proposed Parcels 1, 2, 3 and 4 as illustrated on the <br /> found in Appendix C. The pert test location for Parcel l was directly south of the <br /> g pad where the leachfield will be installed. The pert test location for Parcel 1 was <br /> the existing well location and structures. <br /> The following information describes the preparation of the percolation test borings and the actual <br /> pert testing: (§ 6.2, 6.3 and 6.5) On July 19,2005, one shallow pert test boring of 42 inches in <br /> depth was hand-drilled on proposed Parcels 1, 2, 3 and 4. Only shallow depth borings were drilled <br /> and pert tested because leachlines will ultimately manage the majority of effluent flows from any <br /> new structure. The sidewalls of the shallow borings were scored with a pry-bar and the loose <br /> material removed. Two inches of fine gravel was placed at the bottom and three-inch perforated <br /> PVC pipe was inserted in the test borings. All test borings were pre-saturated on July 19, 2005 at <br /> 0900 hrs with 12 inches of water. <br /> (§ 6.4) On July 20, 2005, 0600 hrs,percolation testing commenced for all four borings. There was <br /> no standing water after the 24-hour soak period in the perc tests borings, as illustrated in Table 1 <br /> below. Consequently, EHD Perc Test Procedure#2 was conducted for all four test borings. The last <br /> half hour of the tests was witnessed by David Van Dyne of the San Joaquin County Environmental <br /> Health Department. <br /> (§ 5.4 and 6.8) The following Table illustrates the proposed Parcel number,potential septic system <br /> structure based on depth of passing perc rates, proposed acreage, post soak period status and perc <br /> test results for the respective perc test depths: <br /> TABLE 1 <br /> PERCOLATION TEST RESULTS AND RELATED DATA <br /> PROPOSED PARCEL PROPOSED SHALLOW POST SOAK PERC TEST <br /> AND POTENTIAL <br /> SEPTIC SYSTEM ACREAGE PERCOLATION TEST PERIOD RESULTS <br /> STRUCTURE DEPTHS STATUS <br /> Parcel 1 12.97 Acres 42 INCHES No Standing 3.8 min/in <br /> Existing Leachlines and Water in Hole <br /> Sumps(?) <br /> (Has Two Existing Wells) <br /> Parcel 2 12.97 Acres 42 INCHES No standing 15.6 min/in <br /> Leachlines and Water in Hol, <br /> Sumps(?) <br /> Parcel 3 12.93 Acres 42 INCHES No Standing 3.6 min/in <br /> Leachlines Water in Hole <br /> Parcel 4 46.16 Acres 42 INCHES No Standing L4.7 min/in <br /> Leachlines and Water in Hole <br /> Sumps(?) <br /> (Has One Existing Well) <br /> Chesney Consulting <br />