AMERICAN NATIONAL STANDARD K61.1.1981 <br /> for the Storage and Handling of Agricultural (a) With a marking identifying compliance <br /> .Ammonia,"M-1, in effect at the time of installa- with the rules of the Code under which the <br /> tion, are acceptable for continued use. container is constructed. <br /> 2.1.3 The appurtenances of each system shall (b) With a notation on the container and system <br /> be approved. underground installation.nameplate when the stem is designed for <br /> 2.2 Requirements for Construction and Test (c) With the name and address of the fabricator <br /> Including Skid Containers Other of the container or the trade name of the container <br /> of Containers <br /> ( and with the date of fabrication. <br /> than Refrigerated Storage Tanks)(See Exception (d) With the water capacity of the container in <br /> in Paragraph 4.1.3). pounds at 60 F or gallons, U.S. Standard. <br /> 2.2.1 Containers used with systems covered in (e) With the design pressure in pounds per <br /> Section 3, 6, 7 and 8 shall be constructed and square inch gage. <br /> tested in accordance with the Code except that (fl With the wall thickness of the shell and <br /> construction under Table UW 12 at a basic joint heads. <br /> efficiency of under 80% is not authorized. (g) With the outside surface area in square <br /> feet. <br /> 2.2.2 Containers built in accordance with the (h) With minimum temperature in Fahrenheit <br /> Code,do not have to comply with paragraphs UC for which the container is designed. <br /> 125 through UG 128 inclusive, and paragraphs (i) Marking specified on container shall be on <br /> UG 132 and 133. the container itself or on a nameplate perma- <br /> 2.2.3 Containers other than refrigerated nently affixed thereto. <br /> storage containers shall be constructed to comply 2.3.3 Each container or system covered in <br /> with one or more of the following additional Sections 3, 6.7 and 8 shall be fitted with a liquid <br /> requirements. level gage indicating the maximum level to <br /> Containers shall be stress relieved which the container may be filled with liquid <br /> 2.2.3.1 <br /> ( ' after fabrication a procedure stress <br /> accordance anhydrous ammonia at temperatures between 20 <br /> with the Code,or F(-6.7 C)and 100 F(37.8 C)except on containers <br /> provided with fixed maximum level indicators, <br /> 2.2.3.2 Cold formed heads,when used shall such as fixed length dip tubes,or containers that <br /> be stress relieved, or are filled by weight. Markings shall be in <br /> 2.2.3.3 Hot formed heads shall be used. increments of not more than 20 F (-6.7 C). <br /> 2.3.4 All container openings,except for safety <br /> 2.2.4 Welding for the repair or alteration of relief devices or level indicators,shall be marked, <br /> the shell shall be done In compliance with the stenciled, tagged or decaled to indicate whether <br /> National Board Inspection Code and with pro- the opening is in liquid or vapor service when the <br /> cedures detailed in ASME Code Section IX and container is filled to the maximum allowable <br /> the Code under which the container was fabri- filling density. <br /> cated.Other welding is permitted only on saddle <br /> Elates,lugs,or brackets attached to the container 2.4 Marking Refrigerated Containers <br /> y the container manufacturer. <br /> (See Section 4.3, Marking Refrigerated <br /> 2.2.5 All containers, except refrigerated Containers) <br /> storage tanks with a design pressure of 15 psig <br /> (103.42 kPa)and less,and containers constructed 2.5 Location of Containers <br /> in accordance with Specifications of the DOT, 2,5.1 Consideration shall be given to the <br /> shall be inspected by a person having a current effects of ammonia as well as to <br /> certificate of competency from the National ' physiological <br /> Board of Boiler and Pressure Vessel Inspectors. adjacent fire hazards in selecting the location for <br /> a storage container. Containers shall be located <br /> outside of buildings or in buildings or sections <br /> 2.3 Markings on Non-Refrigerated Con- <br /> tainers and Systems Other Than DOT thereof especially approved for this purpose. <br /> Containers 2.5.2 Containers shall be located at least 50 <br /> 2.3.1 System nameplates,when required,shall feet(15.2 m) from a dug well or other sources of <br /> be permanently attached to the system so as to be Potable water supply; unless the container is a <br /> readily accessible for inspection and shall include part of a water treatment installation. <br /> C� markings as prescribed in 2.3.2. 2.5.3 The location of permanent storage con- <br /> 2.3.2 Each container or system covered in tainers shall be outside densely populated areas. <br /> Sections 3,6,7 and 8 shall be marked as specified 2.5.4 Container locations shall comply with <br /> in the following: the following tables: <br /> 10 <br />