Laserfiche WebLink
Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with The 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br /> as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. <br /> 2) A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> 3) The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances. A <br /> complete set of plans must include fire sprinkler plans, truss design submittals, metal building <br /> shop drawings, structural plans and calculations, plumbing,electrical and mechanical drawings <br /> and energy report. <br /> 4) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading.All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> 5) For each proposed new building, provide the following information on the plans: <br /> A. Description of proposed use <br /> B. Existing and proposed occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers (Yes or No <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> I. Occupant load based on the CBC <br /> J. Occupant load based on the CPC <br /> 6) If high piled combustible storage is to be used in a building, an automatic fire sprinkler system <br /> will be required. <br /> 7) Accessible routes shall be provided per CBC§ 11 B-206. At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones; public streets and sidewalks; and public transportation stops to the accessible building <br /> or facility entrance they serve. Where more than one route is provided, all routes must be <br /> accessible. §11 B-206.2.1 <br /> 8) At least one accessible route shall connect accessible buildings, accessible facilities, <br /> accessible elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 9) At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines,which are <br /> otherwise connected by a circulation path. §11 B-206.2.4 <br /> 10) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> PA-1900042 (UP) Conditions of Approval 3 <br />