My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0005257
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
26618
>
2600 - Land Use Program
>
PA-0500467
>
SU0005257
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:34 AM
Creation date
9/6/2019 11:09:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0005257
PE
2611
FACILITY_NAME
PA-0500467
STREET_NUMBER
26618
Direction
N
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
GALT
APN
00503008
ENTERED_DATE
8/2/2005 12:00:00 AM
SITE_LOCATION
26618 N LOWER SACRAMENTO RD
RECEIVED_DATE
8/1/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOWER SACRAMENTO\26618\PA-0500467\SU0005257\APPL.PDF \MIGRATIONS\L\LOWER SACRAMENTO\26618\PA-0500467\SU0005257\CDD OK.PDF \MIGRATIONS\L\LOWER SACRAMENTO\26618\PA-0500467\SU0005257\EH COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> i <br /> issues shall be submitted to and approved by Environmental Health before the report can be given <br /> final approval. <br /> b. Environmental Health requires a Soil Suitabili (Nitrate Loading Study indicating that the area is <br /> suitable for septic tank usage,- This must be performed prior to recordation of the parcel/final map <br /> (Development Title Section 9-9.105.2[d)).,A review fee of$465.00'must be-paid at,the time:of ' <br /> submittal to.Environmental Health. <br /> The sewage disposal shall comply with the on-site sewage standards of San Joaquin County prior to <br /> approval. A percolationtest that meets absorption rates of the manual of septic tank'practice or the <br /> EPA Design Manual for on-site waste water treatment and disposal systems is required for each <br /> parcel. A permit.fee of$93.00 per percolation hole is required. <br /> NOTE: If percolation tests fail, then additional percolation tests are to be conducted in areas of <br /> proposed engineer-designed septic systems. All percolation tests are to be a minimum of'100 feet <br /> away from wetland boundaries. Prior to approval of percolation tests, a Parcel-Map shafl be <br /> submitted to Environmental Health with dimensions of the septage area required by the percolation <br /> tests under San Joaquin County Sewage Standards; Section 10.3.4. <br /> c. A review fee of$465.00 shall be submitted to Environmental Health along with the engineered <br /> i design criteria for the proposed sewage disposal system for each parcel for review and approval by <br /> i Environmental Health. (Development Title Section 9-1105.2) <br /> i <br /> d. Due to elevation and topographical conditions, engineer-designed septic systems are to be <br /> installed under permit and inspection by Environmental Health with the current fee of$600.00. <br /> (Development Title Sections 9-1103 and 9-1110.4) <br /> NOTE: Estate.type zoning (R-R1)shall require a double-leach field system with alternating <br /> distribution box to be installed at the time of construction per San Joaquin County Sewage <br /> Standards. It is possible that the leach field design may be larger than current Sewage <br /> Standards design criteria. <br /> e. A sewage disposal area as indicated by the septic tank soil suitability study and/or percolation <br /> tests must be shown for each parcel on the final subdivision improvement plans. (Development <br /> Title Section 9-1105.2) <br /> f. The revised subdivision map shall identify any existing wells on this project site. An existing <br /> agricultural well appears to be located along the southern property lime. <br /> g. Connection to an approved public water supply system is required. (Development Title Section 9- <br /> 1120.2) <br /> h. A test well will be required to meet the following: , <br /> (1) Water quality tested to meet requirements of Title 22, CCR (Safe Drinking Water Act). <br /> 2 Water quantity tested to show an adequate source. <br /> O q Y q <br /> (3) Results approved by Environmental Health and Public Works prior to final approval of <br /> improvement plans. <br /> i. The project shall be served by a public water system conforming to the requirements of <br /> Environmental Health and Public Works. The system shall provide adequate domestic and fire <br /> water supply in conformance to the requirements of the County Fire Warden and the local fire <br /> Conditions of Approval - 5 - PA-0500467 <br />
The URL can be used to link to this page
Your browser does not support the video tag.