My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0039867
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
13550
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0039867
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:48:24 PM
Creation date
9/6/2019 3:30:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0039867
PE
4370
STREET_NUMBER
13550
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242-
APN
05502002
ENTERED_DATE
7/25/2019 12:00:00 AM
SITE_LOCATION
13550 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- i <br /> ASTM C494 Standard Specifications for Chemical Admixtures for Concrete. Additives <br /> must be approved by the Engineer. The sand shall be washed clean prior to mixture. <br /> 2. Special care shall be exercised to control the heat of hvdration generated during tilt setting <br /> and curing of cement in the annular seal to prevent deformation of the plastic casing. <br /> Caution should be exercised when using additives that accelerate cement setting as they <br /> tend to increase the rate of heat generation during setting. <br /> 3. Grout used for well abandonment by pressure grouting and for bottom plugs will be a neat <br /> cement grout or bentonite clay mixture. The cement shall meet the requirements. <br /> including latest revisions, of ASTM C150 Standard Specifications for Portland Cement <br /> Type 11. or an approved equivalent. Any additives shall meet the requirements- including <br /> the latest revisions,of ASTM C494 Standard Specifications for Chemical Admixtures tix <br /> Concrete. Additives must be approved by the Engineer. The sand shall be washed clean <br /> prior to mixture. <br /> G. Bottom Plug and Intermediate Bentonite Annular Seal: <br /> 1. The bottom plug, shall be a mixture of equal parts granular bentonite and sand. The sand <br /> shall be washed clean prior to mixing. <br /> 2. Intermediate bentonite clay seals (annular seals) via the annular space surrounding the 6 <br /> inch diameter well casing may be required to prevent vertical movement of lower quality <br /> groundwater. <br /> 3. The intermediate annular seal shall be a mixture of equal parts granular bentonite and <br /> washed sand. <br /> 4. The intervals for the intermediate annular seals will he determined by the Engineer on the <br /> basis of field conditions revealed by the borehole. <br /> H. Well Head and Surface Seal: <br /> I. The well shall be finished with the 6 inch PVC casing rising a minimum of 12 inches <br /> above the ground surface(above grade)and protected with a water tight steel cap. <br /> 2. The concrete for the pad surrounding the well head shall be ready-mixed conforming,to <br /> ASTM C94. 3/4 inch (3/4") maximum aggregate size, 3.000 psi minimum. 28-day <br /> strength,with a two to four inch(2"4")slump,and a minimum of 517 pounds of cement <br /> per cubic yard. <br /> 3. In the case where the pump head and motor assembly is installed directly over the casing, <br /> a watertight seal(gasket)shall be placed between the pump head and the pump base(slab). <br /> or a water-tight seal (gasket) shall be placed between the pump base and the rim of the <br /> casing,or a well cap shall be installed to close the annular opening between the casing and <br /> the pump column pipe. <br /> 4. Where a submersible pump is used,the opening between the well casing and any pipes or <br /> cables which enter the well shall be closed by a watertight seal or well cap. <br /> 5. Openings into the top of the well designed to provide access to the well (e.g. for <br /> measuring,chlorinating,adding gravel.etc.)shall be protected against entrance of surface <br /> waters or foreign matter by installation of watertight caps or plugs. <br /> I) A sounding hole tap (through well cap) must be provided for measurement of <br /> depth to groundwater. <br /> 2) A watertight seal or gasket shall be placed between the pump discharge head <br /> and the discharge line,or in the event of a below-ground discharge.hetween tite <br /> discharge pipe and discharge line. <br /> 6. Openings designed to permit the entrance or egress of air or gas(air or casing vents)shall <br /> terminate above the ground and above the known Flood levels (72 incites above grade), <br /> and shall be protected against the entrance of foreign material by installation of down- <br /> turned and screened"U"bends. <br /> GRINDSTONE JOE'S SUMMARY OF WORK <br /> REPLACEMENT WELL. 01 11 00-5 tune 25,2019 <br />
The URL can be used to link to this page
Your browser does not support the video tag.