My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004091
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
120 (STATE ROUTE 120)
>
800
>
2600 - Land Use Program
>
QX-00-0001
>
SU0004091
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 4:01:42 PM
Creation date
9/8/2019 12:35:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0004091
FACILITY_NAME
QX-00-0001
STREET_NUMBER
800
Direction
E
STREET_NAME
STATE ROUTE 120
City
LATHROP
ENTERED_DATE
5/12/2004 12:00:00 AM
SITE_LOCATION
800 E HWY 120
RECEIVED_DATE
2/23/2000 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\O\HWY 120\800\QX-00-01\SU0004091\CORRESPOND.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
213
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(3) Provide approved toilets for all employees(chemical toilets are acceptable). <br /> (4) Provide handwashing facilities on or near the approved toilets. (Development Title Section 9- <br /> 1415.3[i]) <br /> i. SETBACKS: No excavation shall take place within twenty-five(25)feet of any property line or right- <br /> of-way (nor within the allowed slopes adjacent to said twenty-five (25) foot setback), unless the <br /> elevation prior to excavation is more than that of the abutting property, in which case the elevation <br /> within said twenty-five(25)foot setback shall at no time be less than that of the abuttingproperty, <br /> at <br /> the property line. (Development Title Section 9-1415.3U]) <br /> j. SLOPES: The following provisions do not apply to temporary interior cut slopes(i.e.,working slopes <br /> that do not fall within any of the criteria listed below). Temporary interior cut slopes shall comply with <br /> the Cal OSHA Code of Regulations and/or the Federal OSHA Code of Regulations as applicable. <br /> (DevelopmentTitle Section 9-1415.3[k]) <br /> (1) Terrace Drainage. Drainage plans with calculations shall be submitted for approval to the <br /> Development Services Division for all terraces as part of the Reclamation Plan. <br /> Terraces for reclaimed final slopes shall be sloped back towards the fill and be designed such <br /> that runoff is directed to collection points where it can enter catch basins and be conveyed via <br /> the toe of slope. The spacing of collection points shall <br /> pipes or other acceptable conveyance to <br /> be no greaterthan 1,500 feet, and each reclaimed final slope face that has terracing shall have a <br /> minimum of one (1) down drain. The method of transporting the water along the flow line of the <br /> terrace to the down drain, so as to prevent erosion and possible slope failure,shall be approved <br /> by the Development Services Division. <br /> The method of drainage of terraces for temporary slopes at setback lines shall be submitted to <br /> the Development Services Division for approval. <br /> (2) Slope Stability Factors of Safety. When required by the Title to provide site-specific geologic and <br /> engineering slope stability analysis, the following minimum slope stability factors of safety shall <br /> apply <br /> A. A minimum factor of safety of 1.5 against static deep seated failure. <br /> B. A minimum factor of safety of 1.5 against static surficial failure. <br /> C. A minimum factor of safety of 1.1 against seismic failure; <br /> (3) Temporary Cut Slopes at Setback Lines. Temporary cut slopes (i.e., for limited periods of time, <br /> slopes that are in the process of extraction prior to being backfilled) at setback lines shall not <br /> exceed one (1) foot horizontal to one (1) foot vertical, except that temporary cut slopes at <br /> setback lines to a maximum of one half (1/2) foot horizontal to one (1) foot vertical may be <br /> maintained if site-specific geologic and engineering analysis demonstrate through a slope <br /> stability analysis that the proposed temporary cut slopeswillhHowever,have <br /> the event that stebare <br /> ility <br /> factor of safety as required in Section 9-1415.3(k)(4). <br /> existing structures on the adjacent property (or the immediate potential for structures on the <br /> projected <br /> ed on a slope a of one(1)to one(1he excavation 1l at no)from the property line me be rto the to the toe rof slopeine than a line <br /> project p <br /> (4) Final Slopes. Final cut and/or fill slopes shall not exceed two (2) feet horizontal to one (1) foot <br /> vertical,except as specified below: <br /> QX-00-1\Roorda <br /> San Joaquin County Page 7 <br /> Community Development <br />
The URL can be used to link to this page
Your browser does not support the video tag.