Laserfiche WebLink
i <br /> 3.2 Description of All Past On-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified at the Project Site: Past on-site potentials for <br /> contamination are low. The property has been used for commercial purposes for more than 10 <br /> years. Historically there have been no underground storage tanks. The owner has no <br /> Fi knowledge of above ground storage of chemicals on the subject parcel. A search for use <br /> reports and permits did not yield any concerns for sources of contamination. (See Appendix). <br /> F3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified at the Project Site: Presently there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence <br /> of buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> There are no storage tanks above ground. There are no above ground fuel tanks on the site. 01 <br /> The site contains an existing pond. There are no drainage courses through the property. The <br /> fallow portion of the site contains its own storm runoff. The commercial portion of the <br /> property has an existing storm drainage system. <br /> Fit' <br /> 3.4 Description of All Past Off-Site Potential and/or Known p o Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Past off-site potential <br /> for contamination is low. The subject parcel is located in a mixed rural residential and <br /> commercial community. The residential and commercial properties have historically been <br /> served by septic systems. <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified in the Area of the Project Site: Present <br /> F off-site potential for contamination is low. There is no knowledge of below ground sources (3450 <br /> of contamination in the area of the project site that has or may impact the project site. The <br /> surrounding properties are served by septic systems and public water.0 <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> F CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of Each Potential and/or Known Source of Contamination Identified for <br /> F.F any Real and/or Potential Threat to Human Health and the Environment: The depth to <br /> ground water in this area is approximately 80 feet. Due to this depth, any pesticides, LY 0 <br /> insecticides, and fertilizers used on the property in the past or present would have a minimal <br /> impact to the ground water. <br /> 5.0 CONCLUSIONS S ONS A ND RECOMMENDATIONS SECTION: <br /> F5.1 Discussion of the Above Evaluation: There are no chemical containers for fuel storage <br /> tanks on this site; thus the potential for contamination is low. As was stated above, any S J . <br /> F� pesticides, insecticides, and fertilizers used on the site do not pose any significant potential for <br /> .. contamination to the project site, and no mitigation measures are recommended. <br /> F2 <br /> F' CA051431Surface and Subsurface March, 2007 <br /> f <br />