My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003931_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
11396
>
2600 - Land Use Program
>
PA-0400202
>
SU0003931_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:52:14 PM
Creation date
9/8/2019 12:51:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0003931
PE
2691
FACILITY_NAME
PA-0400202
STREET_NUMBER
11396
Direction
N
STREET_NAME
STATE ROUTE 99
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05926010
ENTERED_DATE
5/11/2004 12:00:00 AM
SITE_LOCATION
11396 N HWY 99 RD
RECEIVED_DATE
5/10/2004 12:00:00 AM
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\11396\PA-0400202\SU0003931\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
w <br /> Septic permit applications have been researched and attached to the <br /> appendix of this report. All applications are for properties within the immediate <br /> area of the subject parcels. Predominantly, the septic systems consists of septic <br /> tanks, leach lines, and pits. Engineered systems have not been required in this <br /> area. <br /> V. GROUND WATER AND DEPTH TESTING <br /> FAccording to the map of "Lines of Equal Depth of Water Wells" published <br /> Fall, 1999, by the San Joaquin County Flood Control and Water Conservation <br /> District, the depth to groundwater at this location is approximately 70 feet. The <br /> gradient of ground water in the project area slopes east to west according to the <br /> F, map lines of equal elevation published in the spring of 1999 by San Joaquin County <br /> Flood Control and Water Conservation District. (See Appendix). Water samples <br /> were taken from the spigot at the office and analyzed for nitrates and DBCP. <br /> Samples were taken by Mike Toy of Dillon & Murphy on January 13, 2004. These <br /> samples were taken using the criteria of Precision Enviro-Tech. The samples were <br /> transported via automobile to Precision Enviro-Tech and released to them (see chain <br /> of custody Appendix). The nitrates were measured at 3.13 mg/l. The DBCP was <br /> F measured as non-detect. (See Appendix for results.) Areas of potential concern <br /> for ground water contamination consist of onsite storage for fuel, which in turn has <br /> a contaminant area around the fuel. However, based on water testing, potential for <br /> I contamination is very low. <br /> Vl. SOIL PROFILE AND PERCOALTION TESTS <br /> One test hole was excavated to a depth of 3.5 feet in the area of potential <br /> I homesite. The purpose of the test hole was to determinepercolation <br /> p p rate in this <br /> area. For approximation location of the test hole, see the Tentative Parcel Map in <br /> the Appendix. The hole was prepared in accordance with County Standards. The <br /> percolation hole was prepared on June 30, 2003. The presoak began on July 2 <br /> and the test performed on July 3, 2003. After 24 hour pre-soak the hole yielded <br /> no remaining water and the 4 hour test was run. <br /> Soils lithology in the general area of the test hole consisted of clay/loam. As <br /> shallow percolation tests did not percolate adequately for use of a conventional <br /> septic system, deep tests were performed by Neil O. Anderson & Associates. (See <br /> E <br /> Appendix) <br /> A copy of the Soils Classification Map prepared by the U.S. Department of <br /> Ag Soil Conservation Service is included in the Appendix. Their map classified the <br /> soils as clay loam. Due to this classification, there should be no potential problems <br /> to special engineering required on future septic systems. <br /> Fi 2 <br />' 1l <br />
The URL can be used to link to this page
Your browser does not support the video tag.