leachfield grade. This will allow some evapotranspiration to take place in the summer since the <br /> leachfield will be in the lawn area. The leachfield trenches and sumps consists of the following <br /> surface area: Each trench=4 ft2 trench sidewalls+2 ft2 bottom of trench x 100 ft length=600 <br /> ft' x 8-100 ft sections=4800 ft. Sumps 4 ft wide x 8 ft deep x 8 ft long= 200 ft2 x 4 sumps= <br /> 800 ft2 : 4800 ft2 + 800 ft2 = 5600 ft' surface area for effluent infiltration <br /> PHASE H: <br /> Base Tank Capacity (BTC)+Average Daily Flow(ADF)x Soil Factor(SF)_ <br /> 2,000 gal BTC + 507 gal ADF x .200 SF=500 lineal feet of leachline <br /> _ 5 - 100 foot sections of leachline pipe= 6,000 square foot leachfield <br /> In addition to the leachline, there should be one sump for every two leachlines for a total of two <br /> sumps. The leachlines should be placed at a depth of 15-20 inches below final leachfield grade. <br /> _ Trench depth should be 36-42 inches. The leachfield trenches and sumps consists of the <br /> following surface area: Each trench=4ft2 ench sidewalls+2 ft2 bottom of trench x 100 ft <br /> length= 600 ft2 x 5-100 ft sections=3000 W. Sumps 4 ft wide x 8 ft deep x 10 ft long=200 ft2 <br /> x 2 sumps=400 ft2: 3000 ft2 +400 ft2 =3400 ft' surface area for effluent infiltration <br /> Several scientific studies have demonstrated that the infiltration capacity of a soil absorption <br /> system is dependant primarily by the formation of the biomat and not by the permeability of the <br /> soil. The biomat is a biological, slimy substance which forms on the soil-effluent interface over <br /> time. Hydraulic loading rates range from a conservative criterion of 0.125 gal/ft2/day to <br /> 0.5 gal/ft2/day for a percolation rate of approximately 1 min/in. These application rate are based <br /> on trench side wall areas only. <br /> IMPACT MITIGATION <br /> Environmental impact from nitrogen has been mitigated within the septic system design by the <br /> following methods: First,by the use of three- 2,000 gallon septic tanks in series, there will be a <br /> higher percentage of solid organic material trapped within the tanks. Additionally, a filter should <br /> be installed on the last tank(e.g. Zabel® or OSI® Filters)before the effluent flows from this tank <br /> to the leachfield. There is evidence that septic tanks have the capability to denitrify nitrate: As <br /> influent enters the first tank,the wastewater has been aerated from flushing action, and from the <br /> aerator on a faucet, etc. But as the oxygen is consumed by microbiological processes, the tank <br /> becomes anaerobic and the microbes begin to use nitrate as an electron acceptor. When the <br /> effluent reaches the third and last tank,there should be virtually no oxygen within the tank <br /> contents, thus theoretically promoting denitrification. <br /> 7 <br /> vaffey Ag Research <br />