My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011280
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
22420
>
2600 - Land Use Program
>
PA-1600194
>
SU0011280
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:59:06 PM
Creation date
9/8/2019 12:55:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011280
PE
2626
FACILITY_NAME
PA-1600194
STREET_NUMBER
22420
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220-
APN
01319005
ENTERED_DATE
3/23/2017 12:00:00 AM
SITE_LOCATION
22420 N HWY 99
RECEIVED_DATE
3/21/2017 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\22420\PA-1600194\SU0011280\CDD OK.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the code. <br /> (3) The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances. A <br /> complete set of plans must include fire sprinkler plans, truss design submittals, metal building <br /> shop drawings, structural plans and calculations, plumbing, electrical and mechanical drawings <br /> and energy report. <br /> (4) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix§ J104 for <br /> foundations. All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> (5) For each proposed new building, provide the following information on the plans: <br /> (A) Description of proposed use <br /> (B) Existing and proposed occupancy Groups <br /> (C) Type of construction <br /> (D) Sprinklers(Yes or No <br /> (E) Number of stories <br /> (F) Building height <br /> (G) Allowable floor area <br /> (H) Proposed floor area <br /> (1) Occupant load based on the CBC <br /> (J) Occupant load based on the CPC <br /> (6) If fire storage is to be provided in a building, an automatic fire sprinkler system will be required. <br /> (7) Accessible routes shall be provided per CBC § 11 B-206. At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones; public streets and sidewalks; and public transportation stops to the accessible building or <br /> facility entrance they serve. Where more than one route is provided, all routes must be <br /> accessible. §11 B-206.2.1 <br /> (8) At least one accessible route shall connect accessible buildings, accessible facilities, accessible <br /> elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> (9) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project. These parking space(s) shall be located as close as possible to <br /> the primary entrance to the building. <br /> (10)Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 of <br /> the California Plumbing Code <br /> PA-1600194 Conditions of Approval 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.