Laserfiche WebLink
Soil Suitability/ Nitrate Loading Study 11'�rracon <br /> { Sun Valley Express Truck Center ■ Acampo, California <br /> August 14, 2017 ■ Terracon Project No. NA177026 <br /> however the deep percolation test met the standard minimum 30 minutes per inch by EHD for <br /> seepage pits. <br /> The parcel appears suitable for the use of a standard septic system utilizing shallow leach lines <br /> with septic pits. Given the low permeable surface soils, the septic pits shall be the primary <br /> absorption measure. All final septic system construction should follow the San Joaquin County <br /> On-Site Wastewater Disposal Standards where applicable. <br /> Based on the method and assumptions described, the results of the nitrate loading balance <br /> indicated that the proposed development at the site should not cause a buildup of nitrates in the <br /> aquifer above 10 mg/L-N. <br /> A groundwater sample could not be collected since there wasn't a water source on site(Refer to <br /> Section 1.4.3). <br /> 4.0 LIMITATIONS <br /> Our professional services were performed, our findings obtained, and our conclusions proposed <br /> in accordance with generally accepted engineering principles and practices. This warranty is in <br /> lieu of all other warranties either expressed or implied. Test findings and statements of <br /> professional opinion do not constitute a guarantee or warranty, expressed or implied. <br /> • <br /> • <br /> Responsive r: Resourceful , Reliable 16 <br />