Laserfiche WebLink
i. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five (5) feet from <br /> any future right-of-way line, including any corner cut-off (snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> j. NO PARKING ZONE: A No Parking Zone shall be approved along the western side of North State <br /> Route 99 West Frontage Road, from the intersection of Woodson Road and extending north 1,350 <br /> feet, and all fees paid to the Department of Public Works prior to issuance of Building Permits. <br /> k. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The following <br /> conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division: <br /> (1) A building permit application including plans will be required. According to state law, the <br /> plans must be prepared by a registered engineer or licensed architect and shall be submitted <br /> for review and approval. An engineer or architect will also be able to help you make <br /> decisions about construction options related to fire sprinklers, allowable areas, firewalls and <br /> any necessary upgrades based on the configuration of the building and your specific needs. <br /> (2) The required plans must be complete at the time of submittal for a building permit. Plans <br /> must address building design and construction, fire and life safety requirements, accessibility <br /> and show compliance with the current California codes and San Joaquin County ordinances, <br /> including the 2013 Editions of the California Building, Electrical, Mechanical, Plumbing, <br /> Energy. Green and Fire Codes. A complete set of plans must include all required <br /> construction documents as required by the building configuration, such as: fire sprinkler <br /> plans, truss calculations, energy calculations, plumbing, electrical and mechanical drawings <br /> as well as structural calculations. <br /> (3) A geotechnical engineering report is required pursuant to Section 1803 of the CBC. All <br /> recommendations of the Soils Report shall be incorporated into the construction drawings. <br /> (4) Pursuant to Table 4-3 of the California Plumbing Code, toilet facilities shall be accessible to <br /> employees at all times, should not be more that 200 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs. The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas. <br /> (5) Parking spaces will be required to accommodate persons with disability in compliance with <br /> Chapter 11B of the California Building Code. These parking space(s) shall be located as <br /> close as possible to the primary entrance to the building. <br /> (6) This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> Requirement per California Code of Regulations,Title 23, Division 2, Chapter 2.7 <br /> I. CALIFORNIA FIRE CODE: The following California Fire Code and San Joaquin County <br /> Ordinance Code requirements will be applicable and shall be incorporated in the construction <br /> plans before submittal to the Community Development Department for a building permit: <br /> (1) CFC 507 Fire Protection Water Supply - Fire flow and hydrants shall be provided for the <br /> proposed project by the use of: CFC Appendix B. <br /> (2) If Fire Protection Systems are required they shall be installed according to the CFC, Chapter 9 <br /> and the appropriate standards and guides adopted in Chapter 35 of the California Building Code <br /> and the California Electrical Code. <br /> PA-1600008 Conditions of Approval 3 <br />