Laserfiche WebLink
i <br /> 3.6 Discussion of general area septic tank repair history: Repair history of the septic tanks in <br /> this area reveals that the leach lines and seepage pits have resulted in consistent unerring <br /> performance. There are been no incidents to report (See Appendix). <br /> 3.7 Description of proposed or ex ecte�maximum (including secondd- t�wellings) <br /> `+ septic tank usage on site: There a two homes on the subject parcel No.aldditional septic <br /> • systems are anticipated at this time. However, each proposed parcel is entitled to a primary home <br /> and a second unit dwelling. <br /> 4.0 GROUNDWATER INFORMATION SECTION <br /> + 4.1 Description of the depth and gradient of groundwater in'the general area: The de _ <br /> ground water in this area is 30 feet and the depth to potable water is approxim ei 180 feet <br /> - according to the map of"Lines of Equal Depth to Groundwater" published Spring, l� <br /> San Joaquin County Flood and Water Conservation District. The gradient descends from east to <br /> west. <br /> 4.2 Description/discussion of any existing and/or potential groundwater <br /> contamination issues in the general location of the site: The concerns for groundwater <br /> contamination in this area are deemed moderate due to the depths involved. Insecticides, <br /> pesticides, and fertilizers typically do not significantly impact groundwater at these depths. <br /> However, as with any agricultural area, there is always a potential for contamination due to <br /> chemicals used in the farming operation. <br /> II <br /> 4.3 Description of location (address/APN), type and construction of well and location <br /> (well head/kitchen tap) where water sample(s) were obtained: Water samples taken from <br /> spigot at the well located at 19912 E. River Road on June 3, 2011 by Mike Toy of <br /> Dillon.&Murphy. <br /> 4.4. Description of cons 'tuents being tested for in the water sample: The water samples are <br /> being tested for nitrates anhi DBCP. <br /> 4.5 Description of how sample was obtained, handled, stored, and transported to the <br /> lab. The water samples were obtained from the spigot at the well located at 19912 E. River Rd. <br /> The samples were taken by Mike Toy of Dillon & Murphy, and driven directly to Precision <br /> Enviro-Tech. The samples were taken and handled in accordance with Precision Enviro-Tech <br /> requirements. The results from the test can be found in the Appendix. <br /> F• 4.6 Complete Chain of Custody document, including printed and signed name of third <br /> party sampler, condition of sample and date and time the sample was submitted to the lab. <br /> For Laboratory samplers, complete laboratory report to inc dc=tlae_ above noted <br /> information: The complete chain of custody document is located in the Appendix. <br /> 2 <br /> r <br />