Laserfiche WebLink
Riviera Estates Page 7 <br /> Our Project Number: E07092A <br /> June 26, 2007 <br /> 4.0 EVALUATION OF IDENTIFIED CONTAMINATION SOURCES <br /> The San Joaquin River is a known shipping channel. The soils and groundwater beneath the <br /> river may be impacted by spills and discharges to the river from upstream. <br /> Rough & Ready Island is a known source of contamination. Based on the distance from the <br /> subject property and the San Joaquin River being between the site and the island, no <br /> contamination is anticipated 'to affect the subject property at this time. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS <br /> Because no staining was observed in the vicinity of the transformers, the transformers are not <br /> considered an environmental threat to the subject property at this time. Should the property <br /> owners or the EHD be concerned about PCB contamination from the transformers, PG&E should <br /> be contacted to test, retrofit, or replace the transformers. <br /> If the existing structures are to be renovated or demolished, a survey to detect lead-based <br /> paints and asbestos-containing materials should be conducted prior to any such activities. <br /> As the site is developed, any stained soil or sources of contamination identified should be <br /> characterized and properly d'sposed in accordance with federal, state, and local regulations. <br /> 6.0 LIMITATIONS <br /> This report was compiled as a Surface and Subsurface Contamination Report for the subject <br /> property. This report contains information and data provided to NOA by several sources. NOA �� '� <br /> in no way warrants the accuracy or completeness of the information provided to this (5a_"> <br /> investigation by those sources. <br /> It should be noted that when an environmental assessment is completed without sample <br /> collection and quantitative analysis of soil and groundwater beneath the site, as in this study, <br /> no statement of scientific CE-rtainty can be made regarding latent subsurface conditions which <br /> may be the result of on-site or off-site sources. The findings and conclusions of this report are <br /> not scientific certainties, but: rather, probabilities based on professional judgement concerning <br /> the significance of the data gathered during the course of this investigation. NOA is not able to <br /> represent that the site or adjoining land contains no hazardous waste, oil, underground storage <br /> tanks, or other latent condition beyond that detected or observed by NOA during the Surface <br /> and Subsurface assessment. The possibility always exists for contaminants to migrate through <br /> surface water, air, or groundwater. <br /> Our office has not been provided with specific criteria for the development of this report other <br /> than a request to evaluate the property in question for possible problems related to toxic or <br /> hazardous agents, nor have we been directed to address any specific questions concerning the <br /> site. Should there be a need to conduct an investigation into a specific question not addressed <br /> in this report, contact our office immediately regarding your concerns. <br /> NEIL O . ANDERSON <br /> AND ASSOCIATES <br /> 902 Industrial Way• Lodi, CA 95240 <br /> 02007 Neil 0. Anderson&Associates, !nc. <br />