Laserfiche WebLink
Sunrise Trucking Page 2 of 3 <br /> Engineered Septic Design <br /> Our Project Number: NA157003G <br /> October 23, 2015 <br /> Septic System Design Parameters <br /> The following table presents the design parameters for the septic system: <br /> Septic Tank Design Parameters <br /> New Septic Tank <br /> Minimum Recommended Tank Size: (1) 1,200 gallon tank <br /> per San Joaquin County Environmental Health Department Standards <br /> Disposal Field Design Parameters <br /> Soil Type: Sand and/or Sandy Loam <br /> Soil Factor: 0.200 <br /> 2 people + 10 future employees = 12 people <br /> Average Daily Flow = 12 people x 15 gpd <br /> Required Leach Line: (ADF) = 180 gallons <br /> 1,200 gal BTCqi <br /> 1,380 gal <br /> 1,380 x 0.200 lineal fe t (LF) of leach <br /> line <br /> Install four (4) leach line with a length of 70 <br /> Suggested New Leach Field Layout: feet. [276 LF /4 line = 69 LF per line] <br /> Please see drawing. <br /> New Septic Tank Volume: New 1,200 gallon monolithic septic tank with <br /> solid pump chamber baffle rated for traffic <br /> loading. Please see design sheets for more <br /> details. <br /> Please see the attached plans regarding further details of the septic system design and <br /> layout. <br /> Plan Review and Inspection <br /> The results of this investigation are not a guarantee that the San Joaquin County EHD <br /> will approve the proposed septic system design and layout on the property. Three copies <br /> of this letter should be submitted with a report review fee to the San Joaquin <br /> Environmental Health Department. Please be aware that the owner is responsible <br /> for these fees. <br /> '44 <br /> ©2015 Neil 0.Anderson&Associates,A Terracon Company. <br />