Laserfiche WebLink
Percolation Test (cont . ) <br /> Five hundred lineal feet of leach lines with a filter bed <br /> of 2000 Sq. Ft . is recommended . The Calculated Tank Capacity <br /> is 2000 gallons . The above recommendations are based on <br /> 80 seats . The existing meeting hall has a kitchen . <br /> The filter bed should be scarified to a depth of four <br /> feet because of compaction of the ground . An expansion <br /> area of at least 2000 Sq . Ft . open land should be set <br /> aside for future use . <br /> A soil profile was performed . Water was encountered at <br /> 916" and rose to 9 ' 0" overnight . <br /> A test for nitrate was performed on a water sample <br /> The result was 42 mg/l . <br /> Engineer ' s Statement <br /> A septic system can be installed to the density proposed <br /> and it is not expected to impact groundwater nor cause <br /> other health hazards . <br /> Dwain C . Tosch <br /> Attachments : <br /> Detail Map <br /> Percolation Field Note Sheet <br /> Nitrate Test Result <br /> Q�pG E SSip,�, <br /> J N0. 14644 <br /> E X n. <br /> \cIvI\- <br />