Laserfiche WebLink
' 3.6 Discussion of general area septic tank repair history: Repair history of the septic tanks in <br /> this area reveal that the leach lines and seepage pits have resulted in consistent unerring <br /> performance. (See Appendix). <br /> ' 3.7 Description of proposed or expected maximum (including second unit dwellings) <br /> septic tank usage on site: Once the Minor Subdivision application(PA 1500198) is completed, <br /> ' there will be nine new parcels for a total of fifteen parcels within the project limits. However, <br /> each parcel will be entitled to a primary unit and a second unit dwelling based on the current zoning. <br /> 4.0 GROUNDWATER INFORMATION SECTION <br /> 4.1 Description of the depth and gradient of groundwater in the general area: The depth to <br /> ' ground water in this area is approximately 140 feet according to the map of "Lines of Equal <br /> Depth to Groundwater" published Spring, 2015, by the San Joaquin County Flood and Water <br /> Conservation District. The gradient descends from east to west. <br /> 4.2 Description/discussion of any existing and/or potential groundwater <br /> contamination issues in the general location of the site: The concerns for groundwater <br /> ' contamination in this area are deemed moderate due to the depths involved. Insecticides, <br /> pesticides, and fertilizers typically do not significantly impact groundwater at these depths, <br /> however, as with any agricultural area, there is always a potential for contamination due to <br /> ' chemicals used in the farming operation. <br /> 4.3 Description of location (address/API), type and construction of well and location <br /> ' (well head/kitchen tap) where water sample(s) were obtained: Water samples were taken <br /> from the faucet at the well located at 26501 State Highway 26 on December 18, 2015 by Mike <br /> Toy of Dillon& Murphy. <br /> 4.4. Description of constituents being tested for in the water sample: The water samples are <br /> ' being tested for nitrates and DBCP. <br /> 4.5 Description of how sample was obtained, handled, stored, and transported to the <br /> lab: The water samples were obtained from the faucet at the well. The samples were taken by <br /> Mike Toy of Dillon& Murphy, and driven directly to Precision Enviro-Tech. The samples were <br /> taken and handled in accordance with Precision Enviro-Tech requirements. The results from the <br /> ' test can be found in the Appendix. <br /> 4.6 Complete Chain of Custody document, including printed and signed name of third <br /> ' party sampler, condition of sample and date and time the sample was submitted to the lab. <br /> For Laboratory samplers, complete laboratory report to include the above noted <br /> information: The complete chain of custody document is located in the Appendix. <br /> ' 5.0 SOIL PROFILE INFORMATION SECTION <br /> 5.1 Site map showing the location,with dimensions, of the soil profiled pit on the parcel. See <br /> Appendix. <br /> 2 <br /> 1 <br />