Laserfiche WebLink
• CONCLUSIONS AND RECOMMENDATIONS <br /> In summary, the soil conditions in the percolation test location appear to be suitable for <br /> use with an on-site septic system. A satisfactory soil percolation rate of 2.6 min/in was <br /> observed in the test location. <br /> The depth of ground water based on recent aquifer levels is estimated to range between <br /> 120 to 125 feet below ground surface. The ground-water flow is to the northwest at a <br /> rate of approximately six feet per mile. <br /> A water sample was collected from the domestic water well. Nitrate was detected in the <br /> sample at a concentration of 5.4 mg/L-N, well below the MCL of 10 mg/L-N. DBCP was <br /> not detected in the sample. <br /> We believe the Site suitable for the use of a standard septic system utilizing leach lines <br /> and seepage pits. No new construction is anticipated. <br /> • <br /> • <br /> LOGE 1710 Page 8 <br />