Laserfiche WebLink
�' v <br /> Soil Suitability Study--APN: 229— 160—01--Parcel Nos. A and B; 11.53 & 10.71Acres,respectively--8 <br /> Parcel No. Test Hole No. Percolation Rate (Min/Inch) Minimum Usable Area(Sq. Ft.) <br /> Deep Test (6' 10 3/4" Max or Type of Septic System <br /> Depth <br /> A A5 30 12,000 +Pits or a Sump System <br /> B BI 6.3 d 12,000 +Pits or a Sump System ft <br /> WELLWATER ANALYSIS: Well water testing and analysis is not an iTYtegral part of <br /> this study. Well water sampling and testing for chemical concentrations is the <br /> responsibility of the property owner who will submit this information separate and apart <br /> from this Soil Suitability Study". <br /> RECOMMENDATIONS: Because of the variety of soils encountered on the subject <br /> property,the noted high clay content in the excavated areas and the careful selection <br /> needed to formally test the soils on the subject property, sump systems or 12,000 square <br /> feet minimum usable disposal areas plus pits are recommended for both Parcels A and B. <br /> ENGINEER'S STATEMENT: Septic systems of the types proposed can be installed <br /> and their construction is not expected to impact groundwater or cause other hazards. <br /> Walter E. Curtis <br /> Attachments: Parcel Map(1) <br /> Well Drillers Log(1) <br /> Appendix 1 <br /> Percolation Data Sheets (3) <br /> T)wnnv W k T)nnna M TnnHR IAAR? CtPinPanl Rnad Fcrtalnn CA US';" PhnnP- 00Q)RIR— )ROS <br />