My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003974 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STEINEGUL
>
16682
>
2600 - Land Use Program
>
PA-0200166
>
SU0003974 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2019 2:25:47 PM
Creation date
9/9/2019 10:20:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0003974
PE
2622
FACILITY_NAME
PA-0200166
STREET_NUMBER
16682
Direction
S
STREET_NAME
STEINEGUL
STREET_TYPE
RD
City
ESCALON
ENTERED_DATE
5/11/2004 12:00:00 AM
SITE_LOCATION
16682 S STEINEGUL RD
RECEIVED_DATE
4/30/2002 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\S\STEINEGUL\16682\PA-0200166\SU0003974\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Soil Suitability Study--APN: 229— 160—01--Parcel Nos. A and B; 11.53 & 10.71Acres,respectively-- 7 <br /> PERCOLATION TESTS: Both Parcels A and B were tested and the percolation <br /> rate determinations were observed by E.H.D. representatives. The parcels are shown on <br /> the attached"Parcel Map". Both shallow and deep percolation tests were conducted and <br /> are reported on in this study. <br /> On March 21, 2002, I excavated Shallow Percolation Test A4. Deep Percolation <br /> Test Holes A1, B1 and A5 also were excavated to the depth and dimensions shown on the <br /> attached "Percolation Data Sheets"for these test holes on that date. The property owner <br /> excavated Deep Percolation Test Holes A 1, B 1 and A5, as well as Deep Percolation Test <br /> Holes A2 and A3 with a backhoe under my supervision on March 21, 2002. I excavated <br /> Shallow Percolation Test Holes A6 and B2 on March 31, 2002. <br /> The Soil Profile Test Hole, SP, was also excavated to a depth of twelve(12) feet <br /> on March 21, 2002. Also on March 21, 2002, an E.H. D. representative was scheduled to <br /> observe the percolation rate determination for Percolation Test Hole B 1 on March 22, <br /> 2002 after the test hole had been presoaked overnight on March 21, 2002. On March 21, <br /> 2002, I conducted a preliminary shallow percolation test on Percolation Test Hole A4, on <br /> Parcel A, as noted on the attached"Field Percolation Data Sheet" on March 21, 2002 <br /> which did not conform to established S.J. County standards as is noted on the "Field <br /> Percolation Sheet" for that day and it was not observed by an E.H.D. representative. <br /> However, a shallow percolation test for Parcel A was conducted later and observed by an <br /> E.H. D. representative on 03/31 and 04/01/02 on Percolation Test Hole A6 and the <br /> resultant percolation rate determination is contained on the "Field Percolation Data <br /> Sheet", dated 03/31/02 and 04/01/02. <br /> As noted above, the property owner also excavated percolation Test Holes A2 and <br /> A3, on Parcel A, with a backhoe under my supervision on March 21, 2002. These two <br /> test holes were not tested beyond their excavation due to the observed clay content and <br /> density encountered in excavating the holes in the field. <br /> An observed percolation rate determination was made on March 22, 2002 for <br /> Percolation Test Hole B 1 and recorded on "Field Percolation Data Sheet", dated 03/21 <br /> and 22/02. Rains prevented an observed percolation rate determination until Percolation <br /> Test Hole Al could be presoaked and tested and reported on until 03/26 and 27/02. <br /> Shallow Percolation Test Hole B2 was presoaked on 03/31/02. The percolation <br /> rate was observed and determined on 04/01/02. <br /> TEST RESULTS: <br /> Parcel No. Test Hole No. Percolation Rate (Min/Inch) Minimum Usable Area(Sq. Ft.) <br /> Shallow Test (3' Deep Max) or Type of Septic System <br /> A A6 30 10,000 or a Sump System <br /> B B2 Failed to meet Co. minimum stds. No recommendation <br /> nennv W k rinnnn M Tnnec 1666) QtP.inPm11 Rnnd Fcralnn CA 95'190 PhnnP- (?nm RZR—?R(K <br />
The URL can be used to link to this page
Your browser does not support the video tag.